background image

iii

Consult the dealer or an experienced radio/TV technician for help.

Changes or modifications not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment. Shielded RS-232 cables are required to be
used to ensure compliance with FCC Part 15, and it is the responsibility of the user to provide and
use shielded RS-232 cables.

FCC Requirements

This equipment complies with Part 68 of the FCC Rules. On the base unit of this equipment is a
label that contains, among other information, the FCC Registration Number and the Ringer
Equivalence Number (REN) for this equipment.

IF REQUESTED, THIS INFORMATION MUST BE GIVEN TO THE TELEPHONE
COMPANY.

The REN is useful to determine the quantity of the devices you may connect to your telephone
line and still have all of those devices ring when your telephone number is called. In most, but not
all areas, the sum of the RENs of all devices connected to one line should not exceed five (5.0).
To be certain of the number of devices you may connect to your line, as determined by the total
RENs, you should contact your local telephone company to determine the maximum REN for
your calling area.

If your equipment causes harm to the telephone network, the telephone company may discontinue
your service temporarily. If possible, they will notify you in advance. But if advance notice isn’t
practical, you will be notified as soon as possible. You will be informed of your right to file a
complaint with the FCC.

Your telephone company may make changes in its facilities, equipment, operations, or
procedures that could affect the proper functioning of your equipment. If they do, you will be
notified in advance to give you an opportunity to maintain uninterrupted telephone service.

If you experience trouble with this telephone equipment, please contact the Address and Phone
number listed in the warranty card for information on obtaining service or repairs.

The telephone company may ask that you disconnect this equipment from the network until the
problem has been corrected or until you are sure the equipment is not malfunctioning.

The user is not authorized to repair or modify the equipment.

This equipment may not be used on coin service provided by the telephone company. Connection
to party lines is subject to state tariffs.

You will find also this information on a sticker on the bottom of the modems case.

The modem is connected to a public switched line using a USOC (Universal Service Order Code)

RJ-11

C modular jack.

Contacting ZyXEL

If you have questions about your ZyXEL product or desire assistance, contact ZyXEL
Communications Corporation in one of the following ways:

Summary of Contents for Comet 336P

Page 1: ...Comet 336P User s Manual Version 1 0 ZyXEL ACCESSING THE INTERNET AND INTRANET...

Page 2: ...Acknowledgments The trademarks and brand names mentioned in this manual are used for plain informational purposes Trademarks and brand names are the property of their respective owners FCC Part 15 In...

Page 3: ...network the telephone companymaydiscontinue your service temporarily If possible they will notify you in advance But if advance notice isn t practical you will be notified as soon as possible You will...

Page 4: ...n North America support zyxel hinet net outside North America Product information Visit our site on the World Wide Web http www zyxel com FTP Information such as ZyXEL software and ROM updates for Nor...

Page 5: ...on 3 Hardware 3 Windows 95 3 Using INF file in the bundled diskette 3 Windows 3 x 4 DOS 4 Fax Modem Enabler 5 Windows NT 4 0 6 Using INF File in the Bundled Diskette 6 3 Basic Modem Operation 9 Unders...

Page 6: ...Stored Phone Numbers 14 Saving Settings and User Profiles 14 Default Modem Settings for PC s 15 4 AT Command Set Summaries 17 Basic AT Command Set 17 Extended AT Command Set 18 Extended AT Command Se...

Page 7: ...intelligent high speed fax modem The modem can be used as both a send receive fax machine and a data modem When connecting to another modem fax the modem automatically negotiates the fastest speed pos...

Page 8: ...2 Introduction...

Page 9: ...indows 95 No any diskette needed in this installation 1 Choose Select from a list of alternate drivers in the New Hardware Found dialog box 2 Select Standard Modem Types and Standard 33600 bps Modem 3...

Page 10: ...ise run the PCMCIA utilities that came with your computer 5 Choose the Ports icon in Control Panel of Windows Main group to configure the COM port and IRQ 6 Install the FAX MODEM application program t...

Page 11: ...n program ONote Insert FAX MODEM before running communication program Fax Modem Enabler MDMEN EXE is the DOS enabler for the PCMCIA Fax Modem For systems without any Card Services you can use the enab...

Page 12: ...er and start Windows NT 4 0 3 From the Control Panel double click the Modem Icon 4 From the Install New Modem dialogue box click the Next button 5 Select Standard modem and click the Next button 6 Cli...

Page 13: ...Installation 7 10 Click the Finish button...

Page 14: ...8 Installation...

Page 15: ...ode In this mode the characters sent to the Comet by your computer are transmitted to the remote modem rather than being interpreted by the Comet as commands Using the Windows 95 Hyper Terminal Progra...

Page 16: ...t will pick up the phone line and try to communicate Normally this command is onlyused to answer an incoming call made from another modem Thus the high pitched noise you will hear from the speaker To...

Page 17: ...ake modem off hook ATH1 Hang up modem on hook ATH0 Manually Disconnecting a Call ATH Making Your First Connection Use the connection you created in the Hyper Terminal program to dial the ZyXEL BBS If...

Page 18: ...terminal window when you type the modem s echo setting is probably set to off In this case issue the ATE1 command When a command is successfully issued and accepted a modem responds with what is calle...

Page 19: ...tocol and error control data compression method used If your modem has detected an incoming ring Result codes can originate from any of eight result code sets The ATXn command lets you choose which se...

Page 20: ...le To store the number 1 714 555 1212 in memory location 2 type AT Z2 17145551212 Enter You can store up to 4 telephone numbers Dialing Stored Phone Numbers The AT command syntax used to dial a store...

Page 21: ...ed for operation with PC type computers and communications software In most cases no additional settings will be required The following are some of the default settings that are used for operation wit...

Page 22: ...16 Basic Modem Operation...

Page 23: ...ash Wait for a 5 second silence before proceeding R Reverse handshake go on line in Answer mode W Wait for second dial tone Remaining digits will be dialed as in band DTMF DL Repeat last ATD command D...

Page 24: ...rier Dn Data Terminal Ready DTR options D0 Ignore DTR signal assume DTR is always ON D1 108 1 DTR OFF ON transition causes dial of the default number D2 108 2 Data Terminal Ready DTR OFF causes the mo...

Page 25: ...n selection R0 CTS tracks RTS response delay is set in S26 R1 Ignore RTS assumes RTS always ON Sn Data Set Ready DSR function selection S0 DSR overridden DSR always ON S1 DSR set ready Tn Modem testin...

Page 26: ...n n 0 3 use AT Dn to set the default dial pointer Extended AT Command Set Command Options Function Description Dn n 0 3 Set default dial pointer at telephone directory location n En Modem error contro...

Page 27: ...seconds 1 255 14 S11 DTMF Touch tone tone duration 1 10 seconds 50 255 95 S12 Escape guard time 1 50 seconds 0 255 50 S18 Test timer seconds 0 255 0 S25 Delay to DTR 1 second for sync mode 1 0 01 for...

Page 28: ...o country restrictions The wait for Dial Tone call progress feature W dial modifier in the dial string will override the value in register S6 The modem always pauses for a minimum of 2 seconds even if...

Page 29: ...his register value is zero the test will not automatically terminate the test must be terminated from the command mode by issuing an T0 or H command When S18 is non zero the modem returns the OK messa...

Page 30: ...00 Result Code Chart Symbol Reference V Supported Reports the DTE Speed as cr lf CONNECT DTE_Speed cr lf CONNECT DTE_Speed Protocol DCE_Speed Error_Control Example CONNECT 38400 V 32bis 14400 V 42bis...

Reviews: