The thermal imager camera can measure from -20~250°C (-4~482°F) and displays the thermal image and temperature.
Furthermore, thermal images can be saved to a micro SD card. Transferring images to the software is included for image report
generation from these saved images.
OPERATION
1.
Power on
Press Trigger (
○
10
) to power on the unit.
2.
Taking a thermal image and temperature
After power on, simply aim the thermal imager camera at the measure target with Lens
(
○
9
) and get the thermal image and temperature immediately. Please make sure the
target area is within the field of view.
Note: There are three cursors on the screen. The cursor shows the temperature of the
object located in the middle of the screen. Other two moving cursors indicate the
highest
and lowest temperatures in the thermal image.
3.
Save thermal images
Press Trigger (
○
10
) to save the thermal image to the micro SD card, press Up Key (
○
3
) or
Down Key (
○
4
) to show the saved images. Press Mode Key (
○
2
) again to return to the
measurement screen. (The default save mode is “Picture”. You can select “Picture’ or
”Movie” mode first. Please see the “FUNCTIONS” section to learn how to setup the “Save
mode”.)
4.
Color palettes
Press Color Palette Key (
○
6
) to select the color palette (4 selectable color palettes) to view thermal images.
Ironbow Rainbow High
contrast
Grayscale
5.
°
C/°F/K
Press Unit Key (
○
5
) for
°
C
、
°F or K transferred.
6.
Power off
Press Mode Key (
○
2
) for more than 3 sec. to power off the unit. Auto power off time is around 1 minute.
FUNCTIONS
Press Mode Key (
○
2
) for scrolling more display functions, then press Up key (
○
3
) or Down key (
○
4
) to change the
functions, then press Trigger (
○
10
) to confirm it.
E
The default emissivity is 0.95, or select other default emissivity: Blackbody:1.0, Matt:0.95, Semi-matt:0.8,
Semi-glossy:0.6, Glossy:0.3
Select Set value to adjust the emissivity (0.1 to 1 step .01).
HAL
When the reading is outside the High Alarm (HAL) or Lo Alarm (LAL) limit, the reading (
HAL: red texts
,
LAL:
blue texts
) shown at the top right corner of screen will flash with two short beep sound constantly.
Select Set HA temp or Set LA temp to adjust the limits or select ON/OFF to turn on/off the alert
.
( step .01)
LAL
Power off
The default setting is “ Auto off 1 min”, you can select other default value: 5, 10, 20 minutes or “ No auto off ”.
Manually power off the device by pressing Mode Key (
○
2
) for 3 seconds.
Backlight
Selectable 3 levels of brightness.
Set time
Set the date and time in MM/DD/YYYY (month/day/year) and HH/MM/SS (hour/minute/second) formats.
Time stamp
Turn on Time stamp to save thermal images with real-time stamp.
Turn off Time stamp to hide date and time on stored thermal images.
Erase file
Select All picture! to clear all stored thermal images.
Select All movie! to clear all stored videos.
Save mode
Select Picture to save thermal images in image mode. (BMP and Excel formats)
Select Movie to save thermal images in video mode.
Noise filter
Turn on Filter
to reduce noise in an image.
Turn off Filter
to display real image noise.
Language
Selectable English/ Germany/Dutch/Italian
STORAGE & CLEANING
It should be stored at room temperature. The sensor lens is the most delicate part of the thermometer. The lens should be kept
clean at all times, care should be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol.
Allowing the lens to fully dry before using the thermometer. Do not submerge any part of the thermometer.
BATTERIES
The thermometer incorporates visual low battery indication as follows:
‘Battery OK’: measurements
are possible
‘Battery Low’: battery needs to be
replaced, measurements are still possible
‘Battery Exhausted’: measurements are
not possible
When the ‘Low Battery’ icon indicates the battery is low, the battery should be replaced immediately with AA, 1.5V batteries.
Please note: It is important to turn the instrument off before replacing the battery otherwise the thermometer may malfunction.
Dispose of used battery promptly and keep away from children.
SPECIFICATION
Thermal Image Resolution
32*31
Measurement Range
-20~250°C (-4~482°F)
Accuracy (Tamb=20~26°C)
±
2% of reading, or 2°C(4°F) whichever is greater
Thermal Sensitivity
0.1°C(0.1°F)
Frame Rate
9Hz
Field of View
40*40 deg
Emissivity Range
0.95 default – adjustable 0.1 to 1 step .01
Focus Focus
free
LCD (inch)
2.8
LCD Type
Color
Image Storage
Stores up to 25000 images, BMP format.
Memory Type
Support 8G micro SD card
Spectral Range
8~14um
Interface USB
Battery Type
AA*4
* IP54 Splash Proof