INSTALLATION

MOUNT HEIGHTS

DUCTING

10"

36"

96"

Min 24"-Max 32"

Minimum mount height between range top to
hood bottom should be no less than 24".

Maximum mount height should be no higher
than 32".

It is important to install the hood at the 
proper mounting height. Hoods mounted too
low could result in heat damage and fire haz-
ard; while hoods mounted too high will be
hard to reach and will loose its performance
and efficiency.

If available, also refer range manufacturer's
height clearance requirements and recom-
mended hood mounting height above range.

A minimum of 6" round or 3-1/4” x 10"rectangular
duct must be used to maintain maximum air flow
efficiency.

Always use rigid type metal ducts only.
Flexible ducts could restrict air flow by up to 50%.

Also use calculation (on right) to compute total
available duct run when using elbows, transitions
and caps.

ALWAYS, when possible, reduce the number or
transitions and turns. If long duct run is required,
increase duct size from 6" to 7 or 8". If a reducer
is used, install a long reducer instead of a pancake
reducer. Reduce duct size as far away from open-
ing as possible.

If turns or transitions are required:
Install as far away from opening and as far
apart, between 2, as possible.

Duct Run Calculation:

Maximum run

6" or 3-1/4” x 10" duct                           

Deduct:
each 90 Elbow used                                
each 45 elbow used                                
each 6" to 3/14 x 10"
transition used                                        
each 3/14 x 10" to 6"
each 3/14 x 10" to 6"
transition used                                        
Side Wall Cap w/ damper                         
Roof Cap                                                

100 FT

15 FT

9 FT

1 FT

5 FT

30 FT
30 FT

e.g.- 1 roof cap, 2x90 elbows, 1 x 45 elbow used:

=30' + 30' + 9' =69' used, 31' available for straight duct runs.

Models: AK7000, AK7036, AK7042   

Page 1

Minimum Duct Size:

Round:
6" minimum 
Rectangular:
3-1/4” x 10”

INSTALLATION

DUCTING

NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,attics or
garages. All exhaust must be ducted to the outside.

Use metal ductwork only.

Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.

Some Ducting Options:

WARNING FIRE HAZARD

Side wall cap
w/ gravity damper

Side wall cap
w/ gravity damper

Soffit or crawl space

Roof Pitch w/ 
Flashing & Cap

Rear Ducting

Models: AK7000, AK7036, AK7042    

Page 2

Summary of Contents for AK700

Page 1: ...D WXE RU VKRZHU K 0DNH VXUH WKH SRZHU LV RII EHIRUH LQVWDOOLQJ ZLULQJ RU PDLQWHQDQFLQJ 2EAD ALL NSTRUCTIONS BEFORE NSTALLING AND OPERATING THIS APPLIANCE MPORTANT 3AFETY OTICE 5SE ARE AND NSTALLATION...

Page 2: ...4 4 2 3 OOD AFFLE FILTERS v v ALOGEN LIGHT BULBS PRE INSTALLED ARDWARE PACKET CONTAINING v DRYWALL SCREWS v DRYWALL SCREWS v DRYWALL SCREWS v WASHERS WIRE CONNECTORS TO X RECTANGULAR TRANSICION ADAPTE...

Page 3: ...ducer is used install a long reducer instead of a pancake reducer Reduce duct size as far away from open ing as possible If turns or transitions are required Install as far away from opening and as fa...

Page 4: ...ension cord or adapter plug with this appliance Follow National electrical codes or prevailing local codes and ordinances Electrical Supply This appliance requires a 120V 60Hz electrical supply and co...

Page 5: ...d check for leaks around duct tape duct silver tape 6 Duct opening cutout 4 Add 1x2 wood strips 3 Baffle filters INSTALLATION CONVERTIBLE OPTIONS Models AK7000 AK7036 AK7042 Page 6 This range hood is...

Page 6: ...RZHU VWDUWV XS RQ VSHHG OHYHO LQ DXWR PRGH DQG ZLOO DXWRPDWLFDOO DGMXVW WKH IDQ VSHHG DFFRUGLQJO KLOH LQ DXWR PRGH WKH PDQXDO PRGH LQGLFDWRU LFRQ ZLOO IODVK LQGLFDWLQJ WKDW RX FDQ VWLOO PDQXDOO FKDQJH...

Page 7: ...OKING LTHOUGH THE FILTERS NEVER NEED REPLACEMENT THEY ARE REQUIRED TO BE KEPT CLEAN AFTER APPROXIMATELY EVERY HOURS OF USE 2EMOVING AFFLE ILTERS 0ULL FILTER TOWARD BACK OF RANGE HOOD USING HANDLES 0IV...

Page 8: ...ONSUMABLE PARTS SUCH AS LIGHT BULBS FILTERS AND FUSES 3ERVICES OUTSIDE OF SERVICE AREA AND THE LABOR COST INCURRED IN CONNECTION WITH THE REMOVAL SHIPPING AND REINSTALLATION COST NOR DOES IT COVER ANY...

Page 9: ...lb is loose 1 Metal filter is loose 2 Spring clip is broken 1 The right upper corner of LCD display indicates HI 2 The right upper corner of LCD display indicates LO 3 The right upper corner of LCD di...

Reviews: