background image

clearly written on the outside of the return package. A brief description 
of the problem as well as the R.A. number must also be written down 
on a piece of paper included in the shipping carton. If the unit is under 
warranty, you must provide a copy of your proof of purchase invoice. 
You may obtain an R.A. number by contacting our customer support 
team through our customer support number. All packages returned to 
the service department not displaying a R.A. number on the outside of 
the package will be returned to the shipper.

       

 

Safety 

Precautions

Ultraviolet Radiation Warning 

(F8-B Only):

The F8-B (blacklight) fixture contains a high intensity led ultraviolet 
emitter which is concentrated with a fresnel lens. When this fixture is 
used in accordance with the manufacturers operating instructions, no 
hazards exist to most people standing within the beam of the fixture. 
However, individuals suffering from a range of sunlight exposure 
disorders, aphakic and pseudoaphikic, or those individuals receiving 
photosensitive medication may receive discomfort if exposed to 
ultraviolet light.  For reflective, not direct use.  Avoid too frequent or too 
lengthy exposure.  Exposure can cause eye and skin injury and allergic 
reactions. Repeated exposure may cause chronic sun damage and 
skin cancer.  Do not look directly into the fixture while in operation.  
Wear protective eyewear.  Failure to use protective eyewear may result 
in severe burns or long-term injury to the eyes.    

IP Rating (All F8s):

The F8 is rated IP54 for weather resistance: Ingress of dust is not 
entirely prevented, but it will not interfere with satisfactory operation. 
Splashing water or light rain or snow will also have no harmful effect. 
While the F8 is protected against light moisture and dust exposure, 
please protect the instrument when shooting in extreme conditions and 
note that the instrument is not rated to be submerged in water, or 
exposed to prolonged periods of moisture. Always use your best 
judgment and protect the instrument from sustained moisture 
exposure.
    
   
    

Page 3

Summary of Contents for F8-100

Page 1: ...Zylight F8 LED Fresnel User Instructions v10 0 F8 D F8 T F8 B F8 100 The...

Page 2: ...rating condition Carefully check the shipping carton for damage that may have occurred during shipping If the carton appears to be damaged carefully inspect your fixture for any damage and be sure all...

Page 3: ...e are no user serviceable parts inside this unit Do not attempt any repairs yourself doing so will void your manufacturer s warranty In the unlikely event your unit may require service please contact...

Page 4: ...unlight exposure disorders aphakic and pseudoaphikic or those individuals receiving photosensitive medication may receive discomfort if exposed to ultraviolet light For reflective not direct use Avoid...

Page 5: ...re if it becomes damaged During long periods of non use disconnect the fixture s main power Always mount this fixture in safe and stable matter Always use a safety cable as part of a secure installati...

Page 6: ...of the pivot located on each of the yoke ears fig 2 Next set the yoke orientation to lean forward You will notice that the base of the yoke has been shaped so when the yoke mount is vertical in a sta...

Page 7: ...Fig 2 Fig 1 Fig 4 Fig 3 Fig 6 Fig 5 Fig 7 Fig 8 Page 6...

Page 8: ...ck of the fixture and the barn door ear will release fig 4 Make sure that each barn door ear is securely locked into position before proceeding to the next one To properly install the barn doors clip...

Page 9: ...es The forward most and slightly wider 9 1 2 circumference position clip is for securing the barn doors Slide your barn door facing forward into the open ear being sure to safely guide the edge ring o...

Page 10: ...h the unit Power is supplied through a standard 4 pin XLR connector using either the included Worldwide AC Adapter P N 13 17005 or a suitable 14 4V battery Please observe correct polarity Batteries th...

Page 11: ...work properly there will be a small amount of rotational movement that engages and disengages the brake at the focus knob without moving the bellows This is normal operation The center screw that hol...

Page 12: ...ompliant A DMX controller sends DMX data instructions from the controller to the instrument DMX is the control data from the DMX controller sent via 5 pin DMX cable to a single fixture multiple lighti...

Page 13: ...MX Breakout jack built in to the rear of the F8 If the F8 will be the last light in your DMX chain you may plug a 5 pin XLR DMX cable directly into the 5 pin DMX Breakout Jack The F8 is a self termina...

Page 14: ...ur DMX console including turning the instrument on and off as well as all dimming control Plug in a standard 5 pin XLR cable into the DMX Breakout Jack on the F8 if it is the last light in your DMX ch...

Page 15: ...ut 1 Use normal glass cleaner and a soft cloth to wipe down the outside casing 2 Clean the external optics with glass cleaner and a soft cloth as necessary 3 Always be sure to dry all parts completely...

Page 16: ...r or replace the defective product All replaced parts and products become the property of Zylight LLC Repaired or replacement parts and products are warranted for the remaining term of the original wa...

Page 17: ...his warranty gives you specific legal rights and you may also have other rights which vary from state to state This device complies with part 15 of the FCC Rules Operation is subject to the following...

Page 18: ...Page 17 3 4 1 2 F8 Fresnel Parts Diagram 9 7 12 7 20 11 6 18 8 15 10 17 16 21 5 14 19 13...

Page 19: ...45 GHz 10 User Selectable Machined aluminum and high impact plastic Factory 54 2 Channels 11 8 KHz 50 000 hrs Up to 5 600 fps tested full brightness Specifications 1 Fresnel Lens 14 01009 2 Barn Door...

Page 20: ...10718 McCune Avenue Zylight LLC World Headquarters Los Angeles CA 90034 978 244 0011 info zylight com...

Reviews: