6
SIP Account
For SIP account settings, go to SIP Settings -> SIP Account page.
SIP Account Configuration Parameters
•
SIP Server: Enter the IP address or domain name of the SIP server. Default SIP port is 5060, if the SIP
server uses other port number as SIP port, please enter the server address in the format of
“ip_address:port” or “domain_name:port”.
•
User ID: The SIP account number provided by SIP server.
•
Password: The corresponding password of the SIP account.
•
Register Expiration(S): SIP register expiration time.
•
Starting RTP Port: The starting local RTP port number.
•
Enable Integration with ZYCOO IP Audio Center: If the SIP paging gateway device is registering to ZYCOO
IP Audio Center, this parameter needs to be enabled, otherwise do not enable it.
•
Activate: Used to enable or disable the SIP register.