Use an electric drill to drill four mounting holes on the installed wall with 147 (H) x 85 (W)
spacing. Each hole should be able to fit the M6*25mm plastic anchor. The recommended
space size for embedded installation is 142mm (H) x 90mm (W) x 60mm (D).
Use a rubber hammer to drive the plastic anchors into the drilled holes.
Align the device with the four screw holes and use the provided KA4*25mm screws for
fixed installation.
Plug the PoE cable directly into the Ethernet interface of the device’s cable harness.
For outdoor use, it is recommended to use the provided waterproof connector for the
PoE cable. Pass the PoE cable through the waterproof connector, connect it to the
Ethernet interface of the cable harness, and tighten them together.
If you do not use PoE cable but regular network cable and power supply, you need to
plug the power cord into the Power interface of the device’s cable harness.
If you need to connect with any sensors, alarm lights, or other peripheral devices, you
need to connect the device with the provided J2 phoenix connector to the Dry Contact
Relay or DIN output interfaces of the device’s cable harness.
If you need to connect with an amplifier, connect it with the Audio-out connector.
1
2
3
4
5
6
7
Need to open the device’s rear case, press and hold the reset button on the intercom
mainboard for 5 seconds till you hear the voice prompts “Resetting factory defaults,
rebooting...” now release the reset button, and the SIP safety intercom will now reset.
2
Schematic diagram of wiring harness
Reset Facto Defaults
8