Value: 01 DON’t report on/off or multilevel status or and change LED indicator status when paddle is pressed and
Parameter 15 is set to value 0 or 2 (output control disabled).
22: Night Mode Brightness Level---Set the level of brightness the dimmer will turn on to when off and lower paddle held DOWN for 2 seconds
Paramter No: 22(0x16) Size:1 ,Default =0
Value: 00 disable function
Value: 01-99
23: LED Indicator Color
Paramter No: 23(0x17), Size=1,Default =1
Value=0 White
Value=1 Blue
Value=2 Green
Value=3 Red
26: LED Indicator Brightness
Paramter No: 26(0x18), Size=1,Default =1
Value=0 Bright (100%)
Value=1 Medium (60%)
Value=2 Low (30%)
27: Single Tap Behavior: when switch is off and press UPPER paddle 1 time, switch turns on to x brightness(Local Button)
Paramter No: 27(0x19), Size=1,Default =0
Value=0 last brightness level
Value=1 custom value set in parameter 18
Value=2 maximum brightness set in parameter 11
Value=2 full 100% brightness
Support for Association Groups
MS11ZS supports 3 association groups. Group 1 supports 1 node ID,Group 2 and Group 3 Supports maximum of 5 node ID’s
Association group_1:Z-Wave™ Plus Lifeline
Association group_1 is default to associate with the primary controller (Gateway/Hub/Controller) for MS11ZS Status change report,
1. MS11ZS will trigger AUTO report function if the Switch status had been changed.
(ex.Switch Multilevel Report/Indicator Report/Central Scene Notification/ Device Reset Locally Notification)
Association group_2:basic set command on/off controlt
When the output of the MS11ZS is changed, On (0xFF) or Off (0x00). The MS11ZS will automatically send out a related basic set
command. On (0xFF) or Off (0x00) to its associated group.
Association group_3:basic set command on/off controlt
When the output of the MS11ZS is changed, On (0xFF) or Off (0x00). The MS11ZS will automatically send out a related basic set
command. On (0xFF) or Off (0x00) to its associated group.
Restoring Factory Defaults
MS11ZS is removed from the network and will be restored to the factory setting
All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network.
Manual Reset:Press and hold lower paddle for 10 seconds, then LED starts blinking, release paddle and within 2 seconds, click lower paddle 5 times
Remark : All the setting and data will be permanently deleted.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.