The Below listed Command Class are all supported the Security S2

    COMMAND_CLASS_VERSION_V2,
  COMMAND_CLASS_SWITCH_BINARY_V2,
  COMMAND_CLASS_CONFIGURATION_V4,
  COMMAND_CLASS_CENTRAL_SCENE_V3,
  COMMAND_CLASS_ASSOCIATION_V3,
  COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3,
  COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3,
  COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1,
  COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1,
  COMMAND_CLASS_INDICATOR_V3,
  COMMAND_CLASS_POWERLEVEL_V1,
  COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5

Z-Wave™ Configuration Parameters

You may use the below configuration parameters to change settings of the corresponding functionality.

1: Locally Button function
      Paramter No: 1(0x01)     Size:1 Byte     
                               Value: 00(default)    Up Button ON,Down Button OFF 
                               Value: 01                Up Button OFF,Down Button ON
                               Value: 02                Up Button ON/OFF,Down Button ON/OFF
2:Status LED Configuration
      Paramter No: 2(0x02)     Size:1 Byte         
                               Value: 00(default)    Output and the LED are in the different state.
                               Value: 01              Output and the LED are in the same state.
                               Value: 02               LED  Always OFF
                               Value: 03               LED  Always ON
3: Auto Turn-Off Timer  
      Paramter No: 3(0x03),   Size=4,
                               Values:0 (minutes) default;
                               Values: 1 – 65535 (minutes);
5: Auto Turn-Off Timer  
      Paramter No: 5(0x05),   Size=4,
                               Values:0 (minutes) default;
                               Values: 1 – 65535 (minutes);
8:Restores state after power failure
      Paramter No: 8(0x08)     Size:1 Byte         
                               Value: 00                  Output OFF.
                               Value: 01                  Output ON.
                               Value: 02 (default)   The state before a power outage.
11: Enable or Disable OutPut control
      Paramter No: 11(0x0B),  Size=1,Default =1                                        
                               Value=0     disable local button and External Switch control,enable Z-Wave™ control
                               Value=1     enable local button and External Switch control,enable Z-Wave™ control
                               Value=2     disable local button and External Switch control
12: external switch type
      Paramter No: 12(0x0C)    Size:1 ,Default =0
                               Value: 0     toggle switch(device changes status when switch changesstatus)
                               Value: 01    momentary switch
                               Value: 02    electronic add-on switch
13: Behavior when Output control disabled
      Paramter No: 13(0x0D)    Size:1 ,Default =0
                               Value: 0     Report on/off status and change LED indicator 
                                                   when upper  or lower paddle is pressed and Parameter 11 is set to value 0 or 2 (output control disabled).
                               Value: 01    DON’t report on/off status or change LED indicator
                                                   when upper  or lower paddle is pressed and Parameter 11 is set to value 0 or 2 (output control disabled).
14: LED Indicator Color
      Paramter No: 14(0x0E)    Size:1 ,Default =1
                               Value: 0     White
                               Value: 01    Blue
                               Value: 02    Green
                               Value: 03    Red
15: LED Indicator Brightness
      Paramter No: 15(0x0F)    Size:1 ,Default =1
                               Value: 00     Bright (100%)
                               Value: 01    Medium (60%)
                               Value: 02    Low (30%)
16: Association reports
      Paramter No: 16(0x10)    Size:1 ,Default =1
                               Value: 00     Z-Wave™ control:Binary switch report,Manual control: Basic set report
                               Value: 01     Z-Wave™ control:Binary switch report,Manual control:  Binary switch report

Support for Association Groups

MS12ZS supports 3 association groups. Group 1 supports 1 node ID,Group 2 and Group 3 Supports maximum of 5 node ID’s
Association group_1:Z-Wave™ Plus Lifeline
     Association group_1 is default to associate with the primary controller (Gateway/Hub/Controller) for MS12ZS Status change report, 
             1. MS12ZS will trigger AUTO report function if the Switch status had been changed.
                   (ex.Switch Binary Report/Basic Report/Central Scene Notification/ Device Reset Locally Notification)
    Association group_2:basic set command
   When the output of the MS12ZS is changed, On (0xFF) or Off (0x00). The MS12ZS will automatically send out a related  basic set 
    command.   On (0xFF) or Off (0x00) to its associated group.
    Association group_3:basic set command
   When the output of the MS12ZS is changed, On (0xFF) or Off (0x00). The MS12ZS will automatically send out a related  basic set 
    command.   On (0xFF) or Off (0x00) to its associated group.

Restoring Factory Defaults

MS12ZS is removed from the network and will be restored to the factory setting

All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network.
Manual Reset:Press and hold lower paddle for 10 seconds, then LED starts blinking, release paddle and within 2 seconds, click lower paddle 5 times
Remark : All the setting and data will be permanently deleted.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.