background image

FV617 Rev. -  4/17/2017

Page 3

Z6950-SD

Installation Overview

The dispenser is mounted directly to the basin or
counter top.  The control box is mounted below the
basin and the soap tube and sensor connector are
run through the basin or counter.

1.

Feed the soap tube and sensor connector through the
mounting hole in the basin.  The dispenser should
face forward as shown.

Spout Installation

2.

Ensure that the mounting adapter is oriented as
shown, with the soap tube and sensor connector
running through the cutout.  Tighten the mounting nut.

Summary of Contents for Serio Series

Page 1: ...edy shall be limited to the replacement of the defective goods Before installation and use the purchaser shall determine the suitability of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantability is expressly excluded If the products sold hereunder are consumer products the imp...

Page 2: ...crews Z6950 SD Common Parts Required Tools Z6957 SD Hand Drill Drill Bits 3 16 Phillips Head Screwdriver Pliers Power supply Power Consumption Sensing Distance Length of Sensing Cable Soap Bottle Volume Dispensed Volume Soap Viscosity Operating Temperature AC110V DC 6V Standby 0 4W Operation 1 2W 4 1 16 36 1000 ml 34 fl oz 1 25 ml 100 3800 cPs 34 131 F Serio Series Nachi Series ...

Page 3: ...nd the soap tube and sensor connector are run through the basin or counter 1 Feed the soap tube and sensor connector through the mounting hole in the basin The dispenser should face forward as shown Spout Installation 2 Ensure that the mounting adapter is oriented as shown with the soap tube and sensor connector running through the cutout Tighten the mounting nut ...

Page 4: ...nnector through the wall and reattach the body to the base by tightening the retention screws Note It is recommended to horizontally offset the soap dispenser spout with the faucet 4 6 and to install vertically 6 10 above the sink drain at the same height as the faucet To comply with ADA standards the center point of the soap dispenser spout must be less than 50 from finished floor Installation Ov...

Page 5: ... the control box 4 Push the soap tube onto the outlet connection on the control box Secure the tube with the clamp 1 Remove the soap bottle from the control box by unscrewing the soap bottle counter clockwise Fill the soap bottle with soap of the appropriate viscosity Do not over fill the soap bottle 2 Re attach the soap bottle to the control box making sure that the soap input tube is inside the ...

Page 6: ...from other cleaning chemicals solvents to prevent potential damages to the sensor and or electronics It is recommended to flush the system with warm water every 3 to 6 months With a minimal amount of soap in the soap bottle fill the soap bottle with warm water Screw the soap bottle back onto the control box and press the green system prime button Hold down the button until all of the water has bee...

Reviews: