Product Code

Size

Circuits

Connections

QHPM-2S

1" Inlet

2

3/4"

QHPM-3S

1" Inlet

3

3/4"

QHPM-4S

1" Inlet

4

3/4"

QHPM-5S

1" Inlet

5

3/4"

QHPM-6S

1" Inlet

6

3/4"

QHPM-7S

1" Inlet

7

3/4"

QHPM-8S

1" Inlet

8

3/4"

QHPM-9S

1" Inlet

9

3/4"

QHPM-10S

1" Inlet

10

3/4"

QHPM-11S

1" Inlet

11

3/4"

QHPM-12S

1" Inlet

12

3/4"

1. Standard: CJ/T 251-2007, GB/T1220-92

2.  Material: Manifold Body: Type 304 Stainless Steel 

Port Connection: Chrome Plated Brass 
Seal: EPDM, Flow Meters: ABS, Nylon, PC, Stainless

3.   Technical  data: 

• Applicable medium: hot and cold water, mixture of water and  
   Propylene Glycol 
• Maximum pressure: 145 psi [1.0 MPa] 
• Applicable temperature range: 32-185°F [0-85°C] 
• Maximum temperature: 194°F [90°C] 
• Flow adjustment range: 0-1.32 gpm [0-5 lpm] 
• Main inlet/outlet size: 1", Sub inlet/outlet size: ¾" 

4. Accessories: ball valves, drain valves, automatic air vents

  Technical Data

3

  Specifications

Summary of Contents for QHPM-2S

Page 1: ...QHPM Stainless Steel Heating Manifold Operating Instructions ...

Page 2: ...50 4 13 105 3 31 84 5 35 136 QHPM 6S 8 203 19 55 496 5 1 96 50 4 13 105 3 31 84 5 35 136 QHPM 7S 8 203 21 52 546 5 1 96 50 4 13 105 3 31 84 5 35 136 QHPM 8S 8 203 23 49 596 5 1 96 50 4 13 105 3 31 84 5 35 136 QHPM 9S 8 203 25 46 646 5 1 96 50 4 13 105 3 31 84 5 35 136 QHPM 10S 8 203 27 43 696 5 1 96 50 4 13 105 3 31 84 5 35 136 QHPM 11S 8 203 29 39 746 5 1 96 50 4 13 105 3 31 84 5 35 136 QHPM 12S ...

Page 3: ...1220 92 2 Material Manifold Body Type 304 Stainless Steel Port Connection Chrome Plated Brass Seal EPDM Flow Meters ABS Nylon PC Stainless 3 Technical data Applicable medium hot and cold water mixture of water and Propylene Glycol Maximum pressure 145 psi 1 0 MPa Applicable temperature range 32 185 F 0 85 C Maximum temperature 194 F 90 C Flow adjustment range 0 1 32 gpm 0 5 lpm Main inlet outlet s...

Page 4: ...Attach the tubing to the appropriate circuit and header Using the spanner tighten the compression nut Repeat procedure for all remaining circuits Connecting The Heating Circuits 4 ...

Page 5: ...Typical manifold piping configuration example Sample Configuration 5 ...

Page 6: ...nt Remove the set ring To increase flow turn the flow meter counter clockwise To decrease flow turn flow meter clockwise Reattach the set ring Repeat procedure for all remaining flow meters Flow Meter Adjustment And Operation 6 ...

Page 7: ......

Page 8: ...OMMERCE TX USA 75428 PHONE 855 ONE ZURN 855 663 9876 FAX 1 800 209 2148 In Canada ZURN INDUSTRIES LIMITED 3544 NASHUA DRIVE MISSISSAUGA ONTARIO L4V 1L2 PHONE 905 405 8272 FA X 905 405 1292 www zurn com Form No ZMKTG370 65 Rev 10 12 ...

Reviews: