ZURN Connected Aqua-FIT Serio Z6950-XL-S-W2 Installation, Operation, Maintenance And Parts Manual Download Page 1

LIMITED WARRANTY

All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the 

date of purchase. Decorative finishes warranted for one year. We will replace at no costs goods that prove defective provided we are 

notified in writing of such defect and the goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly 

maintained and used in accordance with instructions. We shall not be responsible for any labor charges or any loss, injury or damages 

whatsoever, including incidental or consequential damages. The sole and exclusive remedy shall be limited to the replacement of the 

defective goods. Before installation and use, the purchaser shall determine the suitability of the product for his intended use and the 

purchaser assumes all risk and liability whatever in connection therewith. Where permitted by law, the implied warranty of merchantability 

is expressly excluded. If the products sold hereunder are “consumer products,” the implied warranty of merchantability is limited to a 

period of three years and shall be limited solely to the replacement of the defective goods. All weights stated in our catalogs and lists 

are approximate and are not guaranteed.

Sensor-Operated Lavatory Faucets with Smart Connected Features

®

NOTICE: READ ENTIRE MANUAL PRIOR TO INSTALLING PRODUCT.

Z6955-XL-S-W2

Z6950-XL-S-W2

Connected Aqua-FIT

®

Battery Powered Faucets

Serio Series

TM 

-W2

Installation, Operation, Maintenance

and Parts Manual

Patented and Patents Pending

WARNING

: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

ADVERTENCIA: 

Cáncer y daño reproductivo - www.P65Warnings.ca.gov

AVERTISSEMENT: 

Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov

Summary of Contents for Connected Aqua-FIT Serio Z6950-XL-S-W2

Page 1: ...he product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantability is expressly excluded If the products sold hereunder are consumer products the implied warranty of merchantability is limited to a period of three years and shall be limited solely to the replacement of the defective goods ...

Page 2: ...lenoid Filter Shank Mounting Kit Base Gasket Widespread Mounting Kit Aerator and Key Electronics Box with Solenoid Filter Shank Mounting Kit Base Gasket Spout Assembly Required Tools Batteries Batteries Serio Series Package Contents Adjustable Wrench Optional Smooth Jawed Wrench Phillips Head Screwdriver 3 32 M3 Allen Wrenches ...

Page 3: ... or Lithium for monitor Sensor Range Self calibrated dependent upon sink depth and finish Operating Water Pressure 10 125 psi Operational Water Temperature 33 F to 140 F 1 C to 60 C Aerator 1 5 GPM Vandal Resistant Standard Important Safety Information Installer is responsible for ensuring the product is installed and conforms to all plumbing codes and ordinances Do not convert or modify this Zurn...

Page 4: ...n existing device Clean the faucet basin and clear away debris Flush all supply lines before connecting the faucet Failure to do so may result in debris clogging the inlets and or internal control and mixing valve 1 Carefully screw aerator into spout using included tool Take care to not pinch blue o ring 3 Ensure that slot in plastic washer is facing forward Sensor cable should not pass through pl...

Page 5: ...le assembly to shank and connect water line s 3 Connect monitor and electronics module assembly Do not connect cable to the spout at this step 4 Open battery module using supplied 3mm Allen wrench and install supplied batteries in the electronics module Then close and tighten battery module Use AA Lithium Batteries or AAAlkaline batteries but do not mix Lithium with Alkaline Use AA Lithium Batteri...

Page 6: ...on which could flow water for up to 60 seconds Once the flow of water has stopped the faucet is calibrated and can be used normally Do not use any abrasive or chemical cleaners to clean the faucets If abrasives or chemicals are used it can lead to dulling of luster attacking of chrome plating or decorative finishes ONLY use mildly warm soapy water and then wipe the device dry with a clean soft tow...

Page 7: ...alls and reflective surfaces such as metal weaken the signal between the gateway and other devices The LoRa antenna is an omni directional antenna but for best results mount the device so the LoRa antenna is in a vertical position near the top of a wall We recommend conducting a site survey to test the signal strength in different locations before you mount the device Step 4 Mounting the Zurn Gate...

Page 8: ...nsitivity is configured during pack out but the mode can be changed upon installation to optimize the performance within the sink Sensor sensitivity and sensor detection Modes A B may be tried for various lighting conditions sink materials and shape Switch 7 controls the sensitivity On default is normal sensitivity for most sinks providing max range Off set the sensor to a lower sensitivity level ...

Page 9: ...d enough time to calibrate prior to a user or target trying to initiate activa tion Disconnect the sensor and electronic box cables and wait for 30 seconds Reconnect the cables but allow for another 30 seconds before placing hands or a target within the sensor range You should hear a click of the solenoid once calibration is complete Check if protective film was removed from lens Water does not st...

Page 10: ...R sensor and Faucet actuator electronics Restore proper electrical connection as needed Step 2 Test activate the faucet If problem persists see Faucet Troubleshooting section in this guide for other steps Status Good posted in plumbSMART and faucet actuates but usage event data not appearing in plumbSMART Charts Step 1 Verify gateway is powered and LoRa Status LED is ON If not apply power per Zurn...

Page 11: ...nistrator to modify port rules to allow Zurn gateway to access the internet via local router If gateway model is ETH LTE visually verify SIM card is installed in designated slot on the side of gateway If unit has a SIM card then disconnect ethernet cable and power cycle the gateway and wait for unit to initialize and connect LORA LED should turn ON solid after initialization Step 4 If problem stil...

Page 12: ...del Verify product image and model number from plumbSMART product page Details tab against model number cited on product literature and packaging If incorrect contact Zurn Custom Service at 1 855 ONE ZURN 1 855 663 9876 for assistance High Daily Faucet Activate Rate posted in plumbSMART Step 1 Verify faucet is not falsely triggering See Faucet Troubleshooting section for appropriate diagnostic ste...

Page 13: ...retract into the base to eliminate loss Using the same hex wrench depress the ball detent to release spout from base Lift spout and pull sensor cable through deck and base Align spout so that the ball detent is between the 2 holes Press down and turn clockwise Use hex wrench to back set screw out to secure spout To reinstall faucet first drop sensor cable of new spout through the front of the base...

Page 14: ...a by suitable wrench or by hand while applying torque to the supply hose nut Do not over torque the nut P6900 MV ADAP Supplied Adapter with MV and TMV 1 Options To Control Box To Control Box SSH Option SSH Option Supplied Adapter Supplied Adapter 3 8 Copper Tube By Others 3 8 Copper Tube By Others For use with TMV 1 Option For use with MV Option Thermostatic Mixing Valve Mixing Valve Filter and Mi...

Page 15: ...olenoid Item 4 P6950 XL B L Z6955 Sensor Assembly Item 5 P6950 XL EL Mounting Kit Item 6 P6950 43 Widespread Mounting Kit Item 7 P6912 43M Filter Kit Item 8 P6900 120BC Filter Screen Item 9 P6900 MV 7 Mixing Valve with Filter Item 10 P6900 XL MV Description Product No Single Stainless Supply Hose XL Item 12 P6900 SSH Stainless Supply Hose XL Item 13 P6900 SH XL Composite Mixing Valve Adapter Item ...

Page 16: ...TRIES LLC 511 W Freshwater Way Milwaukee WI U S A 53204 Ph 1 855 ONE ZURN Fax 919 775 3541 In Canada ZURN INDUSTRIES LIMITED 7900 Goreway Drive Unit 10 Brampton Ontario L6T 5W6 Ph 905 405 8272 Fax 905 405 1292 Rev B Date 07 29 20 C N No 142919 Prod Dwg No FV723 ...