Adjustable modes and features selection:

To adjust features from default configuration, you must remove the 

battery tray.  Once battery tray is removed you will see the switches.

Purge Features:

  

The purge switches can be configured for 4 modes of operation: Disabled (standard configuration), 12 hour, 24 hours, or 48 hours. 

Purge water flow duration is 2 minutes. Note: Purge activation occurs every switch selected time (0,12, 24, or 48 hours) after last 

activation.

Flow Time:

There are 6 optional time configurations: 30 seconds (standard), 5s, 10s, 15s, 60s, & “Less Time-out”. The “Less Time-out” option 

actually ceases water flow (turns off) after 20 minutes to limit chance of water damage in the event a sink drain becomes blocked .

Sensing Mode (DEFAULT):

 

During this mode the valve will shut off after hands are removed.  If hands are not removed the time out delay will turn off the faucet (ex: 

standard configuration is 30 seconds)  (See Switch Position Diagram shown above)

Metering Mode: 

When hands are detected by the sensor, water will run for ‘ X’ seconds (standard configuration is 30 seconds) before turning off.  (See 

Switch Position Diagram shown above)

Sensor Sensitivity: 

(Default setting: Low):  

The 4 sensor sensitivity options are used for varied sink and environmental conditions. The factory default setting should be ideal 

for most general applications. However, sensor performance can be optimized to adjust for unusual sink finish, material, shape, or 

unusually bright or dark lighting conditions.

Switch 7 controls the sensitivity

-On (default) is normal sensitivity for most sinks providing max range.

-Off set the sensor to a lower sensitivity level for sinks that cause false activation.  The detection range maybe less for all hands.

Switch 8 controls sensor mode

-On (default) enables the mode that filters the effects of flowing in the bottom of problematic sinks.  Detection maybe less for some 

hands.

-Off disable the filter mode, so detection is expanded deeper into the sink for max detection range for all hands.  Some sinks may 

only be able to operate in this mode.

NOTE: After a configuration switch change has been made, disconnect sensor cable from electronics box, wait 30 seconds, then 

reconnect sensor cable and wait 30 seconds to allow the sensor to tune-in the sink characteristics.  

All switches shown in default mode.

 

Switch Position:

 

1

2

3

4

5

6

7

8

 

Purge (Hours)

 

Disable:

 

12: 

24: 

48: 

Off

 

On 

Off

 

On 

Off

 

Off

 

On 

On 

 

Time (Seconds)

 

30: 

5: 

10: 

15: 

60: 

Less Time-out:

  

 

Off

 

On 

Off

 

On 

Off

 

On 

Off

 

Off

 

On 

On 

Off

 

Off

 

Off

 

Off

 

Off

 

Off

 

On 

On 

Mode Select

 

Sensing Mode: 

Metering Mode:  

 

 

 

 

Off

 

On 

 

Sensor Sensitivity

 

Low: 

Normal:

 

Mode A: 

Mode B: 

 

 

 

 

 

Off

 

On 

Off

 

On 

Off

 

Off

 

On 

On 

1   2   3   4   5   6   7   8

ON

OFF

Summary of Contents for Camaya Series

Page 1: ...e finishes warranted for one year We will replace at no costs goods that prove defective provided we are notified in writing of such defect and the goods are returned to us prepaid at Sanford NC with evidence that they have been properly maintained and used in accordance with instructions We shall not be responsible for any labor charges or any loss injury or damages whatsoever including incidenta...

Page 2: ...This Page Intentionally Left Blank ...

Page 3: ...n site Lavatory sink Drain Line Hot and cold water supply line or pre tempered water supply line Installer Servicer should not use pipe dope or teflon thread sealant anywhere on this product most notably threads and connection points Care shall be taken when installing this product to prevent marring of any exposed or decorative surfaces Allen Wrench M3 Supplied Non toothed Wrench Spout Assembly B...

Page 4: ...ogenerator A downstream of electronics module B and filter C to bottom of electronics module NOTE Before installation turn off water supplies to existing faucet and remove faucet if replacing an existing device Clean the faucet basin and clear away debris Flush all supply lines before connecting the faucet Failure to do so may result in debris clogging the inlets and or internal control and mixing...

Page 5: ...en securing the CWB wires to the screw terminals on HW6 unit the BLACK WITH DASHED MARKINGS should be connected to the Positive terminal and the SOLID BLACK wire should be connected to the Negative terminal MJ unit sold separately Note Do not connect more than 8 solenoids to a single transformer BLUE GREEN YELLOW FRAME SAFETY GROUND P6000 HW6 WIRING IN VAC LINE BLACK NEUTRAL WHITE RED MJ HW6 BLUE ...

Page 6: ...FV795 Rev A 05 21 21 Page 4 2 7 Connect sensor inline connector to sensor cable from spout ...

Page 7: ... used for varied sink and environmental conditions The factory default setting should be ideal for most general applications However sensor performance can be optimized to adjust for unusual sink finish material shape or unusually bright or dark lighting conditions Switch 7 controls the sensitivity On default is normal sensitivity for most sinks providing max range Off set the sensor to a lower se...

Page 8: ... after initial installation Sensor may not have had enough time to calibrate prior to a user or target trying to initiate activation Disconnect the sensor and electronic box cables and wait for 30 seconds Reconnect the cables but allow for another 30 seconds before placing hands or a target within the sensor range You should hear a click of the solenoid once calibration is complete Check if protec...

Page 9: ... 8 P6950 XL DC Stainless Supply Hoses XL Item 9 P6900 SSH 2 Single Stainless Steel Hose XL Item 10 P6900 SSH Optional Plug in Power Converter Item 11 P6900 ACA Description Product No HW6 Power Supply Item 12 P6900 HW6 CWB Pigtail Item 13 P6900 CWB Filter Kit Item 14 P6900 120 Filter Screen Item 15 P6900 MV 7 Mixing Valve with Filter Item 16 P6900 XL MV Composite Mixing Valve Adapter Item 17 P6900 ...

Page 10: ...This Page Intentionally Left Blank ...

Page 11: ...This Page Intentionally Left Blank ...

Page 12: ...TRIES LLC 511 W Freshwater Way Milwaukee WI U S A 53204 Ph 1 855 ONE ZURN Fax 919 775 3541 In Canada ZURN INDUSTRIES LIMITED 7900 Goreway Drive Unit 10 Brampton Ontario L6T 5W6 Ph 905 405 8272 Fax 905 405 1292 Rev A Date 05 21 21 C N No 143760 Prod Dwg No FV795 ...

Reviews: