PROBLEM
Yellow L.E.D. light
flashes
3 times
when there are no
users.
Yellow L.E.D. light
flashes continu-
ously when Object
Lock Sensor is
activated by a user.
Red L.E.D. light
flashes.
Not enough water to
fixture or too much
water to fixture.
Valve will not
operate.
Valve does not shut
off.
Valve does not flush
even after Object
Lock Sensor has
been adjusted.
CAUSE
Front of Object Lock Sensor is
covered or Object Lock Sensor is
set too far out, registering the
opposite wall or door as a user.
E-Z Flush unit is in 10-minute
start-up mode (when first acti-
vated), or Sensor Range Reset
Button has been depressed.
Batteries need replacing.
Diaphragm damaged or valve
control stop improperly adjusted.
Object Lock Sensor range set too
close to E-Z Flush, batteries are
dead, or water supply is turned off.
Dirt or debris preventing dia-
phragm from functioning properly.
Batteries are dead.
SOLUTION
Remove item covering sensor or adjust
Object Lock Sensor activation distance.
(See Appendix B – Adjusting the E-Z Flush.)
Yellow L.E.D. light will flash only 3
times,acknowledging a user is in view after
the 10-minute start-up mode.
Replace batteries.
Replace diaphragm and/or adjust valve
control stop.
Adjust Object Lock Sensor, replace batter-
ies, or turn water on. If the E-Z Flush does
not begin to function, call Customer Service
at 1-800-997-3876.
Remove dirt or debris, check by-pass hole
in diaphragm.
Replace batteries. If the E-Z Flush does not
begin to function, call Customer Service at
1-800-997-3876.
Delay Flush = User must
leave the sensor range for 3
seconds before a flush is
generated.
24 Hour Flush = Unit will
automatically flush 24 hours
after the last use.