ZURN AquaSense AV ZEMS Series Installation, Operation, Maintenance And Parts Manual Download Page 11

FV38 Rev. D  2/27/12

Page 11

 1.

P6000-YBYC

Cast Wall Escutcheon & Solder Kit

2A.

P6000-D-SD

Stop Assembly

2B.

P6000-D-WH

Stop Assembly for Wheel Handle

 3.

P6000-VC

Vandal-Resistant Control Stop Cover

 4.

P6000-YBA

Sweat Solder Adapter

 5.

P6000-LL-CP

Valve Body Outside Cover

 6.

P6000-L

Valve Body Inside Cover

 7.

P6000-ECA-WS

Closet Repair Kit (3.5 gpf)

P6000-EUA-WS

Urinal Repair Kit (1.5 gpf)

P6000-ECA-WS1

Low Consumption Closet Kit (1.6 gpf)

P6000-EUA-WS1

Low Consumption Urinal Kit (1.0 gpf)

P6000-ECA-HET

High Efficiency Closet Kit (1.28 gpf)

 8.

Varies

Valve Body

 9.

P6000-B

Vacuum Breaker

10.

PEMS6000-HYM

ZEMS Actuator

11.

PEMS6000-G

ZEMS Escutcheon

12A.

PESS6000-22

ZEMS Closet Sensor Plate

12B.

PESS6000-22A

ZEMS Urinal Sensor Plate

13.

PESS6000-24

ZEMS Closet Override Button

14A.

PEMS6000-26

ZEMS Closet Sensor

14B.

PEMS6000-26A

ZEMS Urinal Sensor

15A.

P6000-A-AA-CP

Chrome Plated 1-1/2” X 8 1/2” Vacuum
Breaker Assembly

P6000-2-A-AA-CP

Chrome Plated 1-1/2” X 21” Vacuum
Breaker Assembly

P6000-3-A-AA-CP

Chrome Plated 1-1/2” X 24” Vacuum
Breaker Assembly

15B.

P6001-A-AA-CP

Chrome Plated 1-1/4” X 8 1/2” Vacuum

20.

P6000-K

Tailpiece Coupling Assembly

21.

P6000-C32

Locking Nut

22.

P6000-C31

Tailpiece O-Ring

23.

P6000-C30

Snap Ring

24.

Varies

Tailpiece

25.

Varies

Adjustable Tailpiece Assembly

26.

P6000-VC

Cast Wall Escutcheon

27.

P6000-YB-CVR

Supply Cover Tube

Breaker Assembly

15C.

P6003-A-AA-CP

Chrome Plated 3/4” X 8 1/2” Vacuum
Breaker Assembly

15D.

P6000-1-A-AA-RB

Rough Brass 1-1/2” X 12 1/2” Vacuum
Breaker Assembly

15E.

P6000-A-AA-RB

Rough Brass 1-1/2” X 5” Vacuum
Breaker Assembly

15F.

P6001-10-A-AA-RB

Rough Brass 1-1/4” X 10” Vacuum
Breaker Assembly

15G.

P6003-10-A-AA-RB

Rough Brass 3/4” X 10” Vacuum
Breaker Assembly

16A.

P6000-H

1 1/2” Spud Coupling Assembly

16B.

P6001-H

1 1/4” Spud Coupling Assembly

16C.

P6003-H

3/4” Spud Coupling Assembly

17A.

P6000-QE3-RB

Rough Brass 1 1/2” Slip Elbow
 Assembly

17B.

P6000-QE3-CP

Chrome Plated 1 1/2” Slip Elbow
 Assembly

18.

Varies

Chrome Plated slotless tube

19.

Varies

Rough Brass Slip Elbow

28.

P6000-VC-SS

Setscrew for Cast Wall Escutcheon

29.

P6000-VC-W-VP

5/64 Allen Wrench

30.

P6000-YB

Sweat Solder Adapter

31.

PESS6000-28

Yoke Screw

32.

PESS6000-25

Yoke

33.

PESS6000-23

Bracket

34.

PESS6000-27

Bracket Screw

32

33

34

31

Summary of Contents for AquaSense AV ZEMS Series

Page 1: ...llation and use the purchaser shall determine the suitability of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantability is expressly excluded If the products sold hereunder are consumer products the implied warranty of merchantability is limited to a period of three years and ...

Page 2: ... Valve Rough In Model ZEMS6140 Model ZEMS6142 Model ZEMS6152 Models ZEMS6001 and ZEMS6003 SENSOR BOX FINISHED WALL 41 4 108 MAX 21 4 57 MIN 111 2 292 21 533 43 4 121 TOP OF FIXTURE 103 4 273 MAX 33 4 95 MIN AS SPECIFIED 21 533 141 2 368 43 4 121 1 I P S SUPPLY MOTOR ACTUATOR ...

Page 3: ...with National Local codes and regulations All plumbing is to be installed in accordance with applicable codes and regulations Water supply lines must be sized to provide an adequate volume of water for each fixture Flush all water lines prior to making connections Sensor units should not be located across from each other or in close proximity to highly reflective surfaces Control Stop should never...

Page 4: ...an operate as many as eight Automatic Sensor equipped Flushometers The Power Converter is supplied with a six foot cord If additional wire is needed from the Power Converter to the Flushometer s use 18 AWG for this by others Do not supply power to the Power Converter until installation of actuator sensor and Flushometer is completed and checked Proper polarity must be observed or damage to one or ...

Page 5: ...pages 2 and 3 STEP 2 Mount Automatic Sensor Figure 3 Install the Zurn Automatic Sensor into the 2 gang electrical box using two 2 long screws provided Ensure that wires from sensor case point up for closet installs and point to the right for urinal installs The rubber push caps will be on the left side of the sensor for closet and at the top for urinal See Figures 4 and 4A The sensor lens faces ou...

Page 6: ... will be sufficient 3 Insert the flush valve tailpiece B into the stop valve A and hand tighten the lock nut D to the stop valve Level the entire unit When all stops are connected to the water supply and water pressure is available flush the supply piping to remove dirt metal chips etc from system A A Before the valve is installed open each stop fully for a brief time and catch the water in a two ...

Page 7: ... to the actuator pipe with setscrew toward actuator Do not tighten setscrew at this time 4 Pull actuator cable through hole with fish tape and back to sensor box Secure armored cable to box with box clamp 5 With escutcheon loose and handle port washer installed push cable into wall The actuator must be angled away from the valve body at this time until the actuator push rod clears the handle port ...

Page 8: ...Flushometer simulating a user Adjust the control stop after each flush until the rate of flow delivered properly cleanses the fixture IMPORTANT NOTE Excessive water flow creates noise while too little flow will not satisfy the needs of the fixture Proper adjustment is made when 1 The plumbing fixture is cleansed after each flush without splashing water out from the lip 2 A quiet flushing cycle is ...

Page 9: ...ure at supply 3 Consult fixture guide for minimum gallons per minute flow and running pressure for satisfactoryperformance 1 Damaged diaphragm 1 Install new P6000 ECA P6000 EUAreplacement kit 2 Enlarged by pass orifice 1 Install new P6000 ECA P6000 EUAreplacement kit 1 Enlarged by pass orifice 1 Install new P6000 ECA P6000 EUAreplacement kit 2 Urinal piston installed in closet 2 Replace urinal pis...

Page 10: ...e Valve ZEMS6000 ZEMS6000 1 ZEMS6000 2 ZEMS6000 3 ZEMS6001 ZEMS6003 ZEMS6140 ZEMS6142 ZEMS6152 ZEMS6190 ZEMS6195 ZEMS6197 Install with flange against spud 14A 13 12A 15A 15B 15C 15D 15D 15E 16A C 16C 16A 16A 17 18 15F 15G 15G 18 18 19 18 17A 17B 17A ...

Page 11: ...Vacuum Breaker Assembly 15B P6001 A AA CP Chrome Plated 1 1 4 X 8 1 2 Vacuum 20 P6000 K Tailpiece Coupling Assembly 21 P6000 C32 Locking Nut 22 P6000 C31 Tailpiece O Ring 23 P6000 C30 Snap Ring 24 Varies Tailpiece 25 Varies Adjustable Tailpiece Assembly 26 P6000 VC Cast Wall Escutcheon 27 P6000 YB CVR Supply Cover Tube Breaker Assembly 15C P6003 A AA CP Chrome Plated 3 4 X 8 1 2 Vacuum Breaker Ass...

Page 12: ...OMMERCIAL BRASS OPERATION 5900 ELWIN BUCHANAN DRIVE SANFORD NC 27330 Phone 1 800 997 3876 Fax 919 775 3541 World Wide Web www zurn com In Canada ZURN INDUSTRIES LIMITED 3544 Nashua Drive Mississauga Ontario L4V1L2 Phone 905 405 8272 Fax 905 405 1292 ...

Reviews: