background image

FV563 Rev.  -  12/2/14
Page 4

11

BATTERIES

S

tep 4.- Connect Power (Choose from the following)

4.1) Battery Installation:

  Loosen the battery cover screw with the supplied allen wrench.  Remove the cover and install the batteries

as indicated on the battery case.  Replace the battery cover and secure.  When installing an IM model, make certain that the supplied
solenoid Y connector is connected so that both solenoids will recieve power.

4.2)

ACA (Alternating Current Adaptor) Plug-In Installation: 

 When using the -ACA plug-in power supply, attached provided inline

connector between sensor and control box to allow ACA connection.  When installing an IM model, make certain that the supplied
solenoid Y connector is connected so that both solenoids will recieve power.

9

Step 3.- Filter or Mixing Tee or Mixing Valve Installation

The supplied inlet filter must be
used with every faucet, unless a
mixing tee or mixing valve is
ordered.

7

3.2) The optional mixing tee assembly (-MT) or mixing valve (-
MV) have integral filters and back checks.  These take the place of
the standard inlet filter when ordered.  The mixing tee or mixing
valve outlet attaches to the electronics module with a 3/8” x 1/2”
ball riser (supplied by others).  Hot and cold water is then sup-
plied to the appropriate 3/8” compression inlets.

8

3.1) The inlet filter is attached directly to the electronic module’s
water inlet.  Tempered water is then supplied to the filter using a
standard 3/8” x 1/2” ball riser (supplied by others.)

-MT

-MV

10

12

SOLENOID Y

CONNECTOR

SOLENOID Y

CONNECTOR

Summary of Contents for Aqua-FIT Serio Series

Page 1: ... replacement of the defective goods Before installation and use the purchaser shall determine the suitability of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantability is expressly excluded If the products sold hereunder are consumer products the implied warranty of merchantab...

Page 2: ...lation Non toothed Wrench Phillips Head Screwdriver Allen Wrench M3 Allen Wrench 3 32 If you are replacing an existing faucet or Aqua FITTM shells turn off water supply and remove the old faucet Clean lavatory rim around the mounting area for the new sensor faucet Serio SeriesTM Faucets 3a Electronics Box with Solenoid Z6950 55 XL 3b Electronics Box with Solenoid Z6950 XL IM 4 Aerator and Key 5 Mo...

Page 3: ...with CP4 or CP8 suffix 1 1b Pass sensor connector and shank through cover plate and fasten to the faucet with the provided screws Step 1 Spout Installation 3 4 Shank Gasket Black Box Hex Nut 5 Shank Gasket Black Box Assembly Hex Nut IMBATTERY BOX 2 3 Ensure that arrows are aligned for all connections 6 Step 2 Electronics Module Installation 2 1 Attach electronics module to the shank using the hex ...

Page 4: ... the supplied solenoid Y connector is connected so that both solenoids will recieve power 9 Step 3 Filter or Mixing Tee or Mixing Valve Installation The supplied inlet filter must be used with every faucet unless a mixing tee or mixing valve is ordered 7 3 2 The optional mixing tee assembly MT or mixing valve MV have integral filters and back checks These take the place of the standard inlet filte...

Page 5: ...installing an IM model make certain that the supplied solenoid Y connector is connected so that both solenoids will recieve power 13 SET SCREW SIDE SPRING LOCK SIDE Before removing the spout be sure to disconnect the sensor cable below the deck so that the cable head can be pulled up through the deck Note location of set screw and spring lock 17 15 INLINE CONNECTOR CWB HW6 MJ HW6 SOLENOID Y CONNEC...

Page 6: ...river to remove the screws on both sides of the black box With screws removed the black box can slide off and allow access to the solenoid for service Accessing the Solenoid Use supplied 3 32 hex wrench to loosen set screw Screw will retract into the base to eliminate loss Using the same hex wrench depress the ball detent to release spout from base Lift spout and pull sensor cable through deck and...

Page 7: ...5 60 20Minutes Off On Off On Off On Off Off On On Off Off Off Off Off Off On On Mode Select Sensing Mode Metering Mode Off On Sensor Resolution 30 20 10 Normal Off On Off On Off Off On On All switches shown in default mode 1 2 3 4 5 6 7 8 ON OFF Sensor Detects Hands and water Turns SensingMode Handsare placed in frontof Sensor WaterTurns On Hands removed fromfront ofSensor WaterTurnsOff Water will...

Page 8: ...dle Screw for Z6950 XL IM model P6950 XL OS 5 4 Cast Cover Plate w Gasket P6950 CP4 Description 6 8 Cast Cover Plate w Gasket P6950 CP8 7 Z6950 Sensor Assembly P6950 XL EL 8 Mounting Kit P6900 43 9 Filter Kit P6900 120 10 Filter Screen P6900 MV 7 11 Mixing Valve w Filter P6900 XL MV 12 Mixing Tee w Filters and Back Checks P6900 XL MT 13 Optional Plug in Power Converter P6900 ACA 14 Single Stainles...

Page 9: ...hen adjust the dip sw itch settings for sensor resolution per the diagram in the installation manual sw itches 7 and 8 Sensor lens could have surface damage scratches or deposit build ups from chemical cleaners Inspect the sensor lens underneath the spout tip May require cleaning damp rag or replacement Remove the battery tray and inspect for visual signs of rust w ater debris Replace battery tray...

Reviews: