FV563 Rev. - 12/2/14
Page 4
11
BATTERIES
S
tep 4.- Connect Power (Choose from the following)
4.1) Battery Installation:
Loosen the battery cover screw with the supplied allen wrench. Remove the cover and install the batteries
as indicated on the battery case. Replace the battery cover and secure. When installing an IM model, make certain that the supplied
solenoid Y connector is connected so that both solenoids will recieve power.
4.2)
ACA (Alternating Current Adaptor) Plug-In Installation:
When using the -ACA plug-in power supply, attached provided inline
connector between sensor and control box to allow ACA connection. When installing an IM model, make certain that the supplied
solenoid Y connector is connected so that both solenoids will recieve power.
9
Step 3.- Filter or Mixing Tee or Mixing Valve Installation
The supplied inlet filter must be
used with every faucet, unless a
mixing tee or mixing valve is
ordered.
7
3.2) The optional mixing tee assembly (-MT) or mixing valve (-
MV) have integral filters and back checks. These take the place of
the standard inlet filter when ordered. The mixing tee or mixing
valve outlet attaches to the electronics module with a 3/8” x 1/2”
ball riser (supplied by others). Hot and cold water is then sup-
plied to the appropriate 3/8” compression inlets.
8
3.1) The inlet filter is attached directly to the electronic module’s
water inlet. Tempered water is then supplied to the filter using a
standard 3/8” x 1/2” ball riser (supplied by others.)
-MT
-MV
10
12
SOLENOID Y
CONNECTOR
SOLENOID Y
CONNECTOR