LIMITED WARRANTY

All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the

date of purchase. Decorative finishes warranted for one year. We will replace at no costs goods that prove defective provided we are

notified in writing of such defect and the goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly

maintained and used in accordance with instructions. We shall not be responsible for any labor charges or any loss, injury or damages

whatsoever, including incidental or consequential damages. The sole and exclusive remedy shall be limited to the replacement of the

defective goods. Before installation and use, the purchaser shall determine the suitability of the product for his intended use and the

purchaser assumes all risk and liability whatever in connection therewith. Where permitted by law, the implied warranty of merchantability

is expressly excluded. If the products sold hereunder are “consumer products,” the implied warranty of merchantability is limited to a

period of three years and shall be limited solely to the replacement of the defective goods. All weights stated in our catalogs and lists are

approximate and are not guaranteed.

Sensor-Operated Battery-Powered
Lavatory Faucets

®

Aqua-FIT

TM

Serio Series

TM

Sensor-Operated Lavatory Faucets
for Battery or Plug-In Installations.

Installation, Operation, Maintenance,
and Parts Manual

Patented and Patents Pending

Z6950-XL-S

Z6955-XL-S

Z6950-XL-IM-S

Summary of Contents for Aqua-FIT Serio Series

Page 1: ... replacement of the defective goods Before installation and use the purchaser shall determine the suitability of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantability is expressly excluded If the products sold hereunder are consumer products the implied warranty of merchantab...

Page 2: ...lation Non toothed Wrench Phillips Head Screwdriver Allen Wrench M3 Allen Wrench 3 32 If you are replacing an existing faucet or Aqua FITTM shells turn off water supply and remove the old faucet Clean lavatory rim around the mounting area for the new sensor faucet Serio SeriesTM Faucets 3a Electronics Box with Solenoid Z6950 55 XL 3b Electronics Box with Solenoid Z6950 XL IM 4 Aerator and Key 5 Mo...

Page 3: ...with CP4 or CP8 suffix 1 1b Pass sensor connector and shank through cover plate and fasten to the faucet with the provided screws Step 1 Spout Installation 3 4 Shank Gasket Black Box Hex Nut 5 Shank Gasket Black Box Assembly Hex Nut IMBATTERY BOX 2 3 Ensure that arrows are aligned for all connections 6 Step 2 Electronics Module Installation 2 1 Attach electronics module to the shank using the hex ...

Page 4: ... the supplied solenoid Y connector is connected so that both solenoids will recieve power 9 Step 3 Filter or Mixing Tee or Mixing Valve Installation The supplied inlet filter must be used with every faucet unless a mixing tee or mixing valve is ordered 7 3 2 The optional mixing tee assembly MT or mixing valve MV have integral filters and back checks These take the place of the standard inlet filte...

Page 5: ...installing an IM model make certain that the supplied solenoid Y connector is connected so that both solenoids will recieve power 13 SET SCREW SIDE SPRING LOCK SIDE Before removing the spout be sure to disconnect the sensor cable below the deck so that the cable head can be pulled up through the deck Note location of set screw and spring lock 17 15 INLINE CONNECTOR CWB HW6 MJ HW6 SOLENOID Y CONNEC...

Page 6: ...river to remove the screws on both sides of the black box With screws removed the black box can slide off and allow access to the solenoid for service Accessing the Solenoid Use supplied 3 32 hex wrench to loosen set screw Screw will retract into the base to eliminate loss Using the same hex wrench depress the ball detent to release spout from base Lift spout and pull sensor cable through deck and...

Page 7: ...5 60 20Minutes Off On Off On Off On Off Off On On Off Off Off Off Off Off On On Mode Select Sensing Mode Metering Mode Off On Sensor Resolution 30 20 10 Normal Off On Off On Off Off On On All switches shown in default mode 1 2 3 4 5 6 7 8 ON OFF Sensor Detects Hands and water Turns SensingMode Handsare placed in frontof Sensor WaterTurns On Hands removed fromfront ofSensor WaterTurnsOff Water will...

Page 8: ...dle Screw for Z6950 XL IM model P6950 XL OS 5 4 Cast Cover Plate w Gasket P6950 CP4 Description 6 8 Cast Cover Plate w Gasket P6950 CP8 7 Z6950 Sensor Assembly P6950 XL EL 8 Mounting Kit P6900 43 9 Filter Kit P6900 120 10 Filter Screen P6900 MV 7 11 Mixing Valve w Filter P6900 XL MV 12 Mixing Tee w Filters and Back Checks P6900 XL MT 13 Optional Plug in Power Converter P6900 ACA 14 Single Stainles...

Page 9: ...hen adjust the dip sw itch settings for sensor resolution per the diagram in the installation manual sw itches 7 and 8 Sensor lens could have surface damage scratches or deposit build ups from chemical cleaners Inspect the sensor lens underneath the spout tip May require cleaning damp rag or replacement Remove the battery tray and inspect for visual signs of rust w ater debris Replace battery tray...