background image

MODEL 350AST 6" (STANDARD & METRIC)

0

5

10

15

0

400

800

1200

1600

2000

FLOW RATES (GPM)

PR

ESSU

RE L

O

SS (

PSI

G

)

0

35

69

104

0.0

25.2

50.5

75.7

100.9

126.2

FLOW RATES (l/s)

PR

ESSU

R

LO

SS 

(k

pa

)

MODEL 350ASTDA 6" (STANDARD & METRIC)

0

5

10

15

0

500

1000

1500

2000

FLOW RATES (GPM)

PR

ESSU

RE L

O

SS (

PSI

G

)

0

35

69

104

0.0

31.5

63.1

94.6

126.2

FLOW RATES (l/s)

PR

ESSU

R

LO

SS 

(k

pa

)

MODEL 350AST 2 1/2", 3" & 4" (STANDARD & METRIC)

0

5

10

15

0

200

400

600

800

FLOW RATES (GPM)

PR

ESSU

RE L

O

SS (

PSI

G

)

0

35

69

104

0.0

12.6

25.2

37.9

50.5

FLOW RATES (l/s)

PR

ESSU

R

LO

SS 

(k

pa

)

Performance Characteristics

ZURN WILKINS

1747 Commerce Way, Paso Robles, CA 93446 Phone:855-663-9876 Fax:805-238-5766

4

®

Proper performance is dependent upon licensed, qualified personnel performing regular, periodic testing according to ZURN WILKINS' 

specifications and prevailing governmental & industry standards and codes and upon following these installation instructions. Failure to 

do so releases ZURN WILKINS of any liability that it might otherwise have with respect to that device. Such failure could also result in 

an improperly functioning device.

IS350AST (REV. 

F

  

1/19

)

3"

 

(80mm)

4"

 

(100mm)

2 1/2"

 

(65mm)

MODEL 350ASTDA 2 1/2", 3" & 4" (STANDARD & METRIC)

0

5

10

15

0

200

400

600

800

FLOW RATES (GPM)

PR

ESSU

RE L

O

SS (

PSI

G

)

0

35

69

104

0.0

12.6

25.2

37.9

50.5

FLOW RATES (l/s)

PR

ESSU

R

LO

SS 

(k

pa

)

6"

 

(150mm)

6"

 

(150mm)

3"

 

(80mm)

4"

 

(100mm)

2 1/2"

 

(65mm)

 Rated Flow (Established by approval agencies)

www.zurn.com

Summary of Contents for 350AST Series

Page 1: ... make field testing possible INDOOR INSTALLATION Indoor installation is preferred in areas that are subject to freezing conditions All the basic installation instructions apply to such installations OUTDOOR INSTALLATION The Model 350AST Series Backflow Pre venter may be installed outdoors only if the device is protected against freezing condi tions Exposure to freezing conditions will result in im...

Page 2: ...the valve you may see both needles drop simultaneously during test due to disc compression The high side needle should eventually hold 2 psi below low side needle if check in not fouled TEST NO 2 TIGHTNESS OF 2 CHECK VALVE REQUIREMENT The static pressure drop across check valve 2 shall be at least 1 0 psid If test cock 4 is not at the highest point of the check valve body then a vertical tube must...

Page 3: ...ify flow direction arrow 2 Gate valves not fully open 2 Turn handles counterclockwise 3 Low supply pressure 3 Attach pressure gauge to test cock 1 and verify pressure ZURN WILKINS 1747 Commerce Way Paso Robles CA 93446 Phone 855 663 9876 Fax 805 238 5766 www zurn com 5 Remove the 2 check by locating one of the two spring loaded plate retainers around the face of the check Pinch the sides of the sp...

Page 4: ...3446 Phone 855 663 9876 Fax 805 238 5766 4 Proper performance is dependent upon licensed qualified personnel performing regular periodic testing according to ZURN WILKINS specifications and prevailing governmental industry standards and codes and upon following these installation instructions Failure to do so releases ZURN WILKINS of any liability that it might otherwise have with respect to that ...

Reviews: