Details
Notes
ZRK-EMLV2-30W-XXDC
IP20 (indoor)
100 - 277 VAC
12VDC or 24VDC
12V: 5A 24V: 2.5A
30W
47 ~ 63Hz
0.99 (fully loaded)
79%
0.5A @ 100VAC
<0.50mA
Shuts down output voltage, recovers
after faulty condition is removed
≤120%
212°F ± 18°F (100°C ± 10°C) Shuts
down output voltage, recovers after
faulty condition is removed
-40°F ~ 140°F (-40°C ~ 60°C)
20 ~ 90%RH. Non condensing
-40°F ~ 176°F (-40°C ~ 80°C),
10 ~ 95%RH
±0.03% /°C [32°F ~ 122°F (0 ~ 50°C)]
10 ~ 500Hz, 2G 10min./ 1 cycle, period
for 60min. Each along X,Y,Z axes
UL (E495946), conforms to
UL1310, certified to CSA STD.C22.2
No. 250.13
I/P-O/P:1880VAC
I/P-O/P:100MΩ/500VDC/25°C/70%RH
FCC Part 15B
0.46lb (210g)
H: 6 1/8” (155mm) W: 2 1/8“ (54mm)
D: 13/16” (20mm)
400Hz
7 years
Working Humidity:
Storage Temp. and
Humidity:
Temp. Coefficient:
Vibration:
Certifications:
Withstand Voltage:
Isolation Resistance:
EMC Emission:
Weight:
Dimensions:
PWM Frequency:
Warranty:
SKU:
Ingress Protection:
Input Voltage:
Output Voltage:
Rated Current:
Rated Power:
Frequency Range:
Power Factor:
Efficiency (Typ.):
AC Current (Max.):
Leakage Current:
Short Circuit:
Overload Protection:
Overheat Protection:
Working Temp:
•
All parameters if not specially mentioned are measured at 120VAC input, rated load and ambient temperature of 25°C.
•
To extend the life of the driver keep the load below 90%.
•
Load on the driver should be within 10%-100%.
•
Loading on the AC dimmer should not be below 40% in order to extend the life of the dimmer.