11 Technical data
11.1
Light sources
This product contains light source of energy efficiency class G.
11.2
Note for testing institutes
Placing thermocouples between the appliance door and the seal can cause lack of leak-
tightness and thus measuring errors.
The usable volume within the meaning of EN 50304 / EN 60350 is obtained with the
shelf guides disassembled.
General note
Maximum load capacity: 3 kg
▪
For appliances with a grill: Keep the appliance door closed while grilling. The heat
could otherwise damage the operating and display elements or the fitted units above.
11.3
Temperature measurement
The temperature inside the cooking space is measured when the cooking space is
empty according to an internationally accepted standard. Own measurements can be im-
precise and are not suitable for checking the accuracy of the temperature.
11.4
Product fiche
In accordance with EU Regulation No.: 66/2014
Brand
–
V-ZUG Ltd
Type of appliance
–
Steam cookers
Model designation
–
CS2T
Model number
23035, 23036, 23039,
23040, 23056, 23059
Mass of appliance without appliance drawer
kg
41
Mass of appliance with appliance drawer
kg
52
Number of cavities
–
1
Heat source per cavity
–
Electricity
Volume per cavity
l
69
Energy consumption in conventional mode
1
)
kWh/cycle
0.69
Energy consumption in hot air / forced convection
mode
2
)
kWh/cycle
0.62
Energy Efficiency Index per cavity
3
)
–
73.8
Measurement and calculation methods used
–
SN EN 60350-1:2016