1.2 Installation of the extraction system
Fig. 1
Fig. 2
1.2.1 Suction line
n
Provide a sufficiently stable and
leveled surface. Ensure that the
housing does not touch the furniture
to avoid noise production by
resonances.
n
If necessary the unit can be leveled by
turning the feet up/down (Fig.1).
n
Plug in the muffle of the enclosed
suction hose to the intake nozzle (2)
and the other side firmly to your intake
system.
Use the enclosed 90° adaptor if
running sideways.
1
Closure
2
Exhaust connection
3
Filter door
16
Diffusor
30
Exhaust Adaptor
1.2.2 Exhaust
n
If using the unit in non-stop operation,
the exhausting air temperature is
increased.
n
To avoid overheating, the exhausting
air must be able to flow out and
spread free.
n
If this is not possible, the diffusor can
be removed and the exhausting air
can be guided with a DN75 hose or
pipe (Fig.2). Therefore use the optional
exhaust-adaptor RD72/DN75 O.No.
896/1103
n
To connect the diffusor to the DN75
hose or pipe you will need the optional
diffusor-holder O.No. 556/0057 (Fig.3)
n
Alternatively it is recommended to
giude the exhaust air to the outside.