IGURE
15 V
ENTILATION AND
H
EAT
-
DISSIPATION
P
RINCIPLES
Note:
As shown in
Figure 15
, the 1–U space can be equipped with a PSU
subrack (+24V DC power supply) or a lightning subrack (if neces-
sary). The 2–U space can be equipped with BBU or transmission
subrack. If no subrack is equipped, configure an air guide panel
or blank panel instead.
The top RF subrack, fan subrack and air guide panel (2U) adopt
the front air intake and top air exhaust mode due to the vertical
placement of RSU modules in the RF subrack.
The BBU fan unit in the baseband subrack internally adopts a right-
to-left ventilation due to the horizontal placement of BBU board.
Two air guide panels (1 U) are each placed at the top and at the
bottom of BBU to form an external air channel with front air intake
and back air exhaust. Air enters the baseband subrack through
two air guide panels, then goes into the BBU from right led by the
fan unit, and finally comes out from the back door after it gets
through the BBU board to the left.