background image

Ÿ

This product should be installed indoors upon completion of any building 
renovations

.

Ÿ

Prior to installation, the device should be stored in a dry, dust-and-mold-
proof place

.

Ÿ

Do not install the 

sensor 

in a place with direct sun exposure, high 

temperature

,

 or humidity

.

Ÿ

Keep away from chemicals, water, and dust

.

Ÿ

Ensure the device is never close to any heat source or open flame to prevent 
fire

.

Ÿ

Ensure the device is connected to an electric power source that does not 
exceed the maximum load power

.

Ÿ

No part of the device may be replaced or repaired by the user

, except for the 

battery.

WARNING

INDOOR ONLY!

This sensor may only be used and installed indoors. 
Outdoor installation will void its warranty.

For best results, mount the sensor within 30 feet from the door and 
around 7 feet from the ground. The 4-in-1 Sensor will detect motion up to 
40 feet depending on mounting location and sensitivity settings.

MOTION DETECTION RANGE

40 FEET

125º

125º

1. Bring the sensor within direct range of your Z-Wave gateway (hub).

2

. Put the Z-Wave hub into exclusion mode (not sure how to do that? 

[email protected])

.

3

Press and release the Z-Wave button with a paperclip twice quickly.

4. Your hub will confirm exclusion and t

he device will disappear from your 

controller's device list

.

The sensor’s wake-up interval is set to 12 hours by default to save battery 
life. 

Y

ou can change the wake-up interval using your controller’s advanced 

settings if available.

During wake-up, the sensor receives communication from the hub (setting 
updates or network information). Long wake-up interval will 

not

 affect 

how o en the sensor reports motion and other values to your hub.

MANUAL WAKE-UP

Press and release the Z-Wave button 

once 

to wake the device up. The LED 

indicator will flash once (blue or orange).
You may need to wake the sensor up manually IF:
1. It doesn’t fully configure during set-up (values are not displayed or errors 

pop up in your hub’s interface)

.

2. You change advanced settings for the sensor and want them to update

.

EXCLUSION (REMOVING / UNPAIRING DEVICE)

FACTORY RESET

WAKE-UP MODE

Ÿ

4 smart sensors in 1 compact device

Ÿ

7 levels of motion sensitivity 

Ÿ

4 modes for motion / temperature LED indicator notifications

Ÿ

Built-in tamper protection

Ÿ

Low battery alerts

Ÿ

Z-Wave Plus + 500 chip more range and longer battery life

Ÿ

AES encryption (security-enabled hub required for best performance)

Ÿ

Model Number: ZSE40 VER. 2.0

Ÿ

Z-Wave Signal Frequency: 908.42 MHz

Ÿ

Power: 1 CR123A battery

Ÿ

Range: Up to 100 feet line of sight 

Ÿ

Operating Temperature: 5-104° F

Ÿ

Installation and Use: Indoor only

5. 

The LED indicator will 

flash 5 times

 (

color depends on room temperature, 

it’s usually blue or yellow

)

 

to signal communication and

 

then turn off to

 

confirm inclusion

. If the sensor flashes once only, try factory reset and go to 

Step 1. If the sensor doesn’t flash at all, try pressing the button more firmly. 

3. 

ADD DEVICE to your hub

CLICK Z-WAVE BUTTON TWICE QUICKLY

4. 

Finalize inclusion at the s

ensor

.

TROUBLESHOOTING

The sensor won’t add to your system?

 

Try this:

1. Initiate 

EXCLUSION

 and click the Z-Wave button on the sensor twice.

2. Make sure the battery 

cover is closed 

tightly when adding the sensor.

3. Click the Z-Wave button on the sensor 

6-7 times

 

quickly

 when adding it.

4. Bring the sensor 

closer

 to your hub, it may be out of range.

5. Double-check if the 

battery

 is inserted correctly.

6. Get troubleshooting tips for your hub at 

www.support.getzooz.com

OPTION 1: MOUNTING BRACKET 

Use the 2 screws included in the box to fix the mounting bracket to flat 
surface of your choice - at least 7 feet above the ground for best results.
Once the bracket is securely installed, carefully slide the 4-in-1 sensor onto 
the bracket and position it by tilting it to either side, upwards, or 
downwards - just like in the images below.

OPTION 2: ADHESIVE TAPE

Use the supplied adhesive tape to fix the sensor to a CLEAN flat surface of 
your choice. Apply the tape as in the pictures below.

Z-Wave button

Use a paperclip

 (included in the 

box)

 to access the Z-Wave button 

for inclusion, exclusion, reset, and 
manual wake-up.

1. Insert the battery.
2. Place the sensor near the location where it will be mounted.

WALL

4-IN-1 SENSOR

ZSE40 VER. 2.0

www.getzooz.com

FEATURES

SPECIFICATIONS

USER MANUAL

Z-WAVE CONTROL

Initiate inclusion (pairing) in

 

the app (or web interface).

Not sure how? Get step-by-step instructions for adding 
the sensor to 

SmartThings

Vera,

 and other hubs here:

www.support.getzooz.com

If your primary controller is missing or inoperable, you may need to reset 
the device to factory settings. To complete the reset process manually, 

OPEN the back cover

 to trigger tamper switch. 

Press and release the Z-

Wave button

 

using a paperclip

 10 TIMES quickly

 (within 10 seconds)

.

 The 

sensor will start flashing immediately and will again flash 5 times a er the 
10 clicks (color depends on room temperature, it’s usually blue or yellow).

NOTE: All previously recorded activity and custom settings will be 
erased from the device’s memory.

MOUNTING

CEILING

CORNER

See 

Advanced Settings 

for ways to optimize 
and customize motion 
detection and activity 
reports.

Reviews: