IMPORTANT SAFETY INFORMATION 

READ AND SAVE THESE INSTRUCTIONS 

 

WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS:  

Installation work and electrical wiring must 

be done by qualified person(s) in accordance with all applicable codes and standards. 

 

CAUTION: 

The installation of a ZOO Fan must be in accordance with the requirements specified in this installation manual and with 

any additional requirements set forth by the national electric code (NEC), ANSI/NFPA 70-1999, and all local codes.  If you are 

unfamiliar with wiring, use a qualified electrician. 

 

WARNING

: To reduce the risk of fire, electric shock, or personal injury, mount directly to a structural framing member. 

WARNING

: To prevent electrical shock and/or injury disconnect fan from power source before you move or service the fan. 

 

Not Suitable for use with solid-state speed controls. 

 

WARNING: 

To reduce the risk of fire, electric shock, and injury to persons, ZOO Fans must be installed only with controllers 

supplied by ZOO Fans.  Other parts cannot be substituted. 

 

CAUTION: 

When service or replacement of a component in the fan requires the removal or disconnection of a safety device, the 

safety device is to be reinstalled or remounted as previously installed. 

 

WARNING: 

Risk of fire, electric shock, or injury to persons during cleaning and user maintenance.  Disconnect the fan from the 

power supply before servicing. 

 

WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 

a)

 

Use this unit only in the manner intended by the manufacturer.  If you have questions, contact the manufacturer.

 

b)

 

Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power 

from being switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent 

warning device, such as a tag, to the service panel.

 

 

WARNING: 

Do not install in a cooking area. 

 

WARNING: 

Fatal electric shock from metal cable glands in the plastic terminal box is possible if incorrectly connected – do not use 

metal cable glands in plastic terminal boxes. 

 

WARNING

: Do not operate the fan in spaces with hazardous or Explosive Material and Vapors. 

 

DANGER:  Rotating equipment.  

Death, severe injury and property damage may result.  ZOO Fans are intended to be hung out-

of-reach of people.  The bottom of the fan must be no less than 3.05m (10’) from any area capable of receiving pedestrian 

traffic. 

 

WARNING:

 Stay alert and use common sense when installing fans.  Do not install fans if tired or under the influence of drugs, 

alcohol, or medication. 

 

CAUTION:  

Only operate the fan within the ranges specified on the motor’s type plate. 

 

WARNING:

 Do not bend the blade brackets when installing, adjusting, or cleaning the fan.  Do not insert foreign objects in 

between rotating fan blades. 

 

CAUTION:

 The ZOO Fans product warranty will not cover equipment damage or failure that is caused by improper installation. 

 

 

 

 

Summary of Contents for H60-EC

Page 1: ...0 38th St Suite 201W Boulder CO 80301 PHONE 303 557 1852 zoofans com REV 09062019 Installation Guide Model H60 EC Covered by the following United States and International Patents D631148S 138172 00179...

Page 2: ...and user maintenance Disconnect the fan from the power supply before servicing WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this unit only in the...

Page 3: ...COMMOTION LECTRIQUE OU DE BLESSURE POUR LES PERSONNES APPLIQUEZ CECI a N utilisez cette unit que de la mani re voulue par le constructeur Si vous avez des questions contactez le constructeur b Avant...

Page 4: ...ARTS ENCLOSED 1 ZOO FANS SPECIFICATIONS 2 LAYOUT 2 INSTALLATION 3 HANGING THE FAN 3 STEP 1 Fasten Main Hanging Cable 3 STEP 2 Fasten Stabilization Tether 4 STEP 3 Secure the Gripples 5 WIRING THE LINE...

Page 5: ...layout of fans wiring and controls 2 Hanging the fans where they ll be most effective and convenient to control 3 Completing the electrical hook up 4 Start up and commissioning 5 Conducting all work...

Page 6: ...or destratification is 100 turnover every hour The availability of a sturdy and secure anchor point for attaching the fan Obstructions such as merchandise inventory racks lighting overhead equipment a...

Page 7: ...2 containing the 8 Cable with 3 8 Stud End Fixing and attach that cable to the hole at the top of the fan s handle as shown in Illustration 1 below NOTE Gripple Installation Guidelines are included wi...

Page 8: ...eyelet and attach the stabilization tether to either attachment point located at 45 on each side of the fan s handle as shown in Illustration 2 below TIP When attaching these cables leave the cables w...

Page 9: ...the Gripples Illustration 3 shows how to secure the Main Hanging Cable to the Truss I Beam unistrut or other appropriate attachment point that can easily support the load of the fan 1 Insert cable th...

Page 10: ...the Truss I Beam or support beam WARNING The Stabilization Tether MUST be installed properly to ensure safe operation of your ZOO Fan 1 Insert cable through Gripple 2 At a 45 angle loop cable over Tr...

Page 11: ...7 2019 ZOO FANS INC ALL RIGHTS RESERVED 1650 38th St Suite 201W Boulder CO 80301 PHONE 303 557 1852 zoofans com REV 09062019 Illustration 5...

Page 12: ...8 2019 ZOO FANS INC ALL RIGHTS RESERVED 1650 38th St Suite 201W Boulder CO 80301 PHONE 303 557 1852 zoofans com REV 09062019 Illustration 6...

Page 13: ...LINE VOLTAGE TO TURN FAN ON OR OFF The motor requires constant power To control on off and speed of the fan use the low voltage control Refer to WIRING THE CONTROL SIGNAL The H60 EC fan is available w...

Page 14: ...ZOO Fans VS 10KPOT 0 10 Volt DC analog signal PWM signal contact Zoo Fans for wiring instructions WARNING Never apply line voltage to the control signals OPTION 1 Wiring AVS EC Auto Please refer to ZO...

Page 15: ...11 2019 ZOO FANS INC ALL RIGHTS RESERVED 1650 38th St Suite 201W Boulder CO 80301 PHONE 303 557 1852 zoofans com REV 09062019...

Page 16: ...ZOO Fans 1650 38th St Suite 201W Boulder CO 80301 Phone 303 557 1852 Fax 720 596 5192 info zoofans com zoofans com...