OPERATING INSTRUCTION
OPERATION
Using the Up and Down button, select your required set
point:
UP
- Increases set point.
DOWN
- Decreases set point.
Confirm “AUTO” icon appears above the third button on the
thermostat to maintain zone comfort based on thermostat set
point, room temperature and duct temperature.
FUNCTION BUTTONS
AUTO
-
Configures controller for AUTO mode or OFF mode
(Hold Auto/Off for 15 seconds to turn SAMOD Off/On)
DUCT
- Pressing this button displays supply air temperature
MENU
- Accesses system configuration functions
DUCT TEMPERATURE
To check the duct temperature press “DUCT” and the current
temperature in the duct will be displayed.
LOCKING SAMOD CONTROLLER
The SAMOD controller can be locked hiding MENU functions
and preventing set point from being changed greater than 2
degrees above or below selected set point. To lock SAMOD
controller, press and hold DUCT button for 10 seconds. To
unlock, press DUCT button for 10 seconds; MENU will be
visible and temperature set point can be changed.
CALIBRATION
Press MENU button and scroll to CALIBRATE using the
Up/Down buttons, when highlighted, press SELECT. Use the
Up/Down to set the desired room temperature, press EXIT to
save.
SETUP AUXILIARY HEAT/REHEAT
Press MENU button and scroll by pressing the Up/Down
buttons through menu options. When SET AUX HEAT option
is highlighted, press SELECT. Two options are offered,
BASEBOARD or REHEAT.
If BASEBOARD is desired press SELECT button to select
desired temperature dead band by scrolling through 2, 3 or 4
degrees, when selection is highlighted, press EXIT. Once
desired HEAT DEAD BAND is set, press EXIT. Follow the
same steps but highlight Reheat if desired.
This will complete the setup for Auxiliary / Reheat.
TEMPERATURE FORMAT
Press MENU button and scroll to TEMPERATURE FORMAT
using the Up/Down buttons, when highlighted, press
SELECT. Use the Up/Down buttons to choose F° or C°, press
SAVE when selection has be made.
DAMPER ADJUSTMENT
The ST series zone dampers are factory set for full open and
close operation. Each damper is equipped with adjustable
stops for field setting the maximum open and minimum close
positions if desired.
The SAMOD is an Auto Changeover thermostat that modulates a zone damper based on supply air and room temperature.
System logic dictates system mode of operation. When duct temperature is 3 degrees or more below room displayed
temperature on the SAMOD thermostat, the mode is set as Cool. When duct temperature is 7 degrees or greater than room
temperature as displayed on SAMOD thermostat, then mode is set for Heat. If duct temperature is neither 3 degrees below
nor 7 degrees above room temperature displayed on SAMOD thermostat, then mode is set for Vent for continuous air
circulation.
UP
DOWN
SET POINT
AUTO / OFF
DUCT TEMP
MENU
ROOM TEMP