Page 11
The ZonarSound System
Installation Manual
Issue 01
Remove the four cover retaining screws from the Slave panel and carefully lift off the cover
and PCB assembly to allow access to the internal connectors. Connect the HV signal as
shown below:
Internal Speaker
Connection
Slave
Loop (HV Out)
Amp (HV In)
Star
Con
nect
ion
Two audio signal connectors enable
daisy-chain or star configuration.
Edge
Clamper
Once all internal cable connections have
been made to Master and Slave panels,
secure them by pushing them into the edge
clamper located in the recess at the side of
the amplifier cover plate:
The amplifier cover plate/PCB assembly can
now be re-fitted.
Once all connections have been made and
the cover plate refitted, use a cable tie to
secure all cables to the cable tie anchor point:
Cable Tie
Anchor Point