background image

10

Limited Warranty

LIMITED WARRANTY:

 Zonar

 

 

warrants that the Hardware provided

under this agreement is free from all material defects in workmanship
under normal use and service. Zonar’s warranty period for its
Hardware is as follows:

V3 Product Line - 5 Years
EVIRTM - 3 Years
All Other Hardware - 1 Year

The above warranty periods run from the date of shipment. Provided
that the Hardware is used and handled as intended, Zonar will
replace any failed or functionally impaired Hardware with equivalent
Hardware in terms of performance and functionality.

This warranty does not apply to any Hardware that has been
misused, altered, willfully abused or that has been damaged due
to improper installation by the customer.† Hardware installations
must follow Zonar’s equipment specific installation guidelines.† If
product returned is determined to be damaged due to any of the
aforementioned circumstances, the Customer will be charged the
price of a refurbished unit plus shipping and handling.

CUSTOMER’S SOLE AND EXCLUSIVE REMEDY AND ZONAR’S
ENTIRE OBLIGATION UNDER THESE LIMITED WARRANTIES for
defective equipment is the repair and replacement of the equipment
free of charge by Zonar. Zonar shall not be liable to Customer or
any third party for any general, special, punitive, incidental, indirect
or consequential damages, or any lost profits or business, arising
out of Zonar’s Subscription Agreement.

FCC Compliance Statement (Part 15.19)
IC Compliance Statement (RSS-210)

This device complies with Part 15 of the FCC Rules and with RSS-
210 of Industry Canada (IC). Operation is subject to the following
two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received,  including

interference that may cause undesired operation.

Warning: (Part 15.21)

Changes or modifications not expressly approved by Zonar Systems
could void the user's authority to operate the equipment.

 

Caution: RF Exposure (OET Bulletin 65)

To comply with FCC RF exposure requirements for mobile
transmitting devices, the antenna(s) used for this transmitter must
be installed to provide a separation distance of at least 20cm (8
Inches) from all persons and must not be co-located or operating
in conjunction with any other antenna or transmitter. Users and
installers must be provided with antenna installation instructions
and transmitter operating conditions for satisfying RF exposure
compliance.

Use only supplied and approved antenna's. Use of unauthorized
antenna's or modifications could impair signal quality, void your
warranty and/or result in violation of FCC regulations.

Industry Canada Compliance Statements

"This device has been designed to operate with an antenna having
a maximum gain of [5] dB.  Antenna having a higher gain is strictly
prohibited per regulations of Industry Canada. The required antenna
impedance is [50] ohms."

"To reduce potential radio interference to other users, the antenna
type and its gain should be so chosen that the equivalent is
isotropically radiated power (EIRP) is not more than that required
for successful communication."

"The installer of this radio equipment must ensure that the antenna
is located or pointed such that it does not emit RF field in excess
of Health Canada limits for the general population; consult Safety
Code 6, obtainable from Health Canada's website, www.hc-
sc.gc.ca/rpb."

WARRANTY & NOTICES

FCC/IC COMPLIANCE

Summary of Contents for Virtual Trainer

Page 1: ...REV 08 24 12 ...

Page 2: ...nt longevity and optimal performance This guide is meant to be a general guideline for the professional installer and technician While we attempt to point out the most common installation questions and issues common sense good housekeeping procedures attention to detail safety adherence and technical competence of the professional installer is critical for a successful installation Please refer to...

Page 3: ... or more of the following US patents 6 671 646 6 804 626 7 557 696 7 117 121 7 362 229 7 564 375 7 680 595 7 776 499 7 808 369 7 944 345 8 106 757 plus EP 2756504 3 and the AU REV 08 24 12 Virtual Trainer Introduction 2 System Overview 4 Equipment 5 System Specifications 6 General Guidelines 7 Installation 8 System Checklist 9 Warranty Notices FCC Compliance 10 Notes 11 ...

Page 4: ...FID to log drivers into vehicle Displays warnings and alerts to improve driver performance Track driver performance over time CUSTOMER On Site Location ZONAR Secure Servers Encrypted Data Transmissions CELL TOWER INTERNET ...

Page 5: ...VIRTUAL TRAINER EQUIPMENT 5 A VIRTUAL TRAINER B VIRTUAL TRAINER Mounting Plate and Mounting Screws Provided C Mounting Plate adhesive pad ...

Page 6: ...will not cause accidents personal injury or property damage For the purposes of this notice Owner you and your means the party including any person authorized by that party to use and or install the Product that has either a purchased the Product or b leased the Product from Zonar Systems Inc or its related companies The Owner of this product is solely responsible for observing safe driving practi...

Page 7: ... the warranty 2 Capture all drill chips during drilling operations Do not allow chips to fall onto equipment furnishings etc 3 Deburr all drill holes on both sides of drilled surface Example deburr tool 4 All drill holes must have a rubber grommet or similar anti chaffing system installed to protect cable assemblies e g plastic conduit 5 Seal all penetration drill holes which may pass rain water C...

Page 8: ...ndows or doors which open to the vehicles exterior to prevent water damage 5 Avoid mounting equipment in difficult to access areas Avoid mounting in areas which do not allow for direct viewing 6 Avoid mounting Zonar Equipment antennas and wiring near other radio equipment e g two way radios PA equipment and high energy electrical sources e g cables relays amplifiers etc 7 Avoid mounting equipment ...

Page 9: ...le Management All cables properly ran no tight radius no interference strain relieved supported service looped Electrical System hookup complies to your established standard Red lead voltage verified 12V constant White lead voltage verified Engine on 12V engine off OV key accessory position with engine off OV Black lead continuity verified Grounded to vehicle chassis Verify crimp integrity Post Jo...

Page 10: ...owing two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Warning Part 15 21 Changes or modifications not expressly approved by Zonar Systems could void the user s authority to operate the equipment Caution RF Exposure OET Bulletin 65 To comply with FCC RF exposure requirem...

Page 11: ...11 NOTES ...

Page 12: ...VIRTUAL TRAINER USERS MANUAL INSTALLATION GUIDE 12 2012 Zonar Systems All Rights Reserved REV 08 24 12 ...

Reviews: