background image

Automated External Defibrillator Trainer2

Operator's Guide

      Extra and/or replacement Remote Controllers are available

      Contact your distributor or ZOLL Medical.

NOTE

1. 

Keep Trainer2 and Remote Controller clean, undamaged, 

 

and free of excessive wear.

2. 

Verify that there are no cracks or loose parts in Trainer2 and

 

Remote Controller.

3. 

Replace Training electrodes as necessary.

MAINTENANCE

Trainer2 does not respond

(green light in status window

is not lit) when 

On/Off

button is pushed

TROUBLESHOOTING

Clean the Trainer2 unit and remote controller with soft, damp

cloth using soap and water, then wipe dry immediately.

Do not immerse any parts in water.

Do not clean with ketones (e.g., MEK, acetone).

Avoid using abrasives on any surface.

Do not sterilize the Trainer2 or the Remote Controller.

CLEANING

 

 

© ZOLL Medical Corporation 2007

TRAINING USE ONLY - NOT FOR CLINICAL USE

REF 9650-XXXX-XX Rev. A 

CPR Metronome On/Off

This control activates the Trainer2's metronome 

which begins to beep at 60 compressions per minute 

(CPM) then automaticallyaccelerates to 100 CPM  

after a few seconds. Metronome beeps are inde-

pendent of the student's actual compression rate 

and continue until the CPR interval times out or until 

the Metronome On/Off button is pressed again.  The 

control and the metronome functions are only active 

during periods when the Trainer2 has prompted 

the rescuer to perform CPR

.

PUSH HARDER Button

Pressing this control button causes the Trainer2 to 

emit a single "PUSH HARDER" voice prompt.  

Instructors should depress this button when the 

student's chest compressions are too shallow.

Good Compressions Control

Pressing this control button causes the Trainer2 to 

emit a "GOOD COMPRESSIONS" voice prompt. To

simulate operation of the AED PLUS defibrillator, 

instructors should use this control to provide 

students with positive feedback about improve-

ments in chest compression depth when they

respond to "PUSH HARDER" prompts.

Remote Controller: Description:

CPR FEEDBACK OPERATION 

The AED PLUS Trainer2 includes controls that allow instructors to simulate 

the voice prompts and text messages issued by the AED PLUS when

rescuers perform CPR.  These controls include:

 

 

Product intended for indoor use only.

WARNING

Do not attempt to plug AED Plus or AED Pro

simulator into connector of Trainer2.

WARNING

This device is for training only. It will not deliver

defibrillation energy.

WARNING

Replace all four “D” batteries

in Trainer2 unit.

Remote Controller does not 

respond (scenario 

selection is not lit) 

when 

view/enter

button is pushed

Replace both “AA” batteries in

Remote Controller.

With new batteries in both, 

Trainer2 fails to respond to 

Remote Controller 

AED Trainer problem / display:

          

Action:

Contact ZOLL 

Technical Service

Do not attempt to take Trainer2 or Remote

Controller apart.  Remove and replace battery

compartment doors only and replace

immediately.

WARNING

On

Off

Trainer2 does not beep or

react to Remote Controller

during CPR interval. 

Re-set scenario and make

certain that CPR metronome

light is on.

No prompt to “GIVE TWO

BREATHS” after “CHECK

BREATHING”

Unit is configured for ERC. 

Change to AHA configuration.

(See Chaning AHA/ERC 

Configurations section of this

Operator’s Guide).

SWITCHING AHA/ERC CONFIGURATION

American Heart Association (AHA) configuration:  Prompt to “GIVE TWO

BREATHS” after “CHECK BREATHING”.

European Resuscitation Council (ERC) configuration:  NO prompt to “GIVE

TWO BREATHS” after “CHECK BREATHING”.

Prompt to “GIVE TWO BREATHS” can be configured into (AHA configuration),

or out of (ERC configuration) the prompt sequence by doing the following:

With the Trainer2 unit off, hold down the Shock Button. Press On/Off Button 

once.  Green light will illuminate at status window to indicate AHA config-

uration (prompt sequence will contain “GIVE TWO BREATHS”).

Press On/Off Button again.  Green light will turn off and red light will illuminate

at status window to indicate ERC configuration (prompt sequence will NOT

contain “GIVE TWO BREATHS”).

Press On/Off Button again to revert to AHA configuration (green light on 

and red light off).

When configured as desired (green = AHA, red = ERC), hold down On/Off

button to turn unit off and store configuration.