This guide is believed to be correct at the time of publication and BICOM takes no responsibility for
consequences from printing error or inaccuracies. Specifications are subject to change without notice.
dS2 AMP or DAC Channel selector:
*B & H
positions have alternate
setups:
To enter/exit the alternate mode, power on the dS2 with Ethernet disconnected and the position rotary
in the A position. After seeing the occasional quick GREEN blinks, press and hold the factory reset
button and before the sweep tone starts within a few seconds, turn the position rotary to B (for Rs+Rb)
or H (for Ls+Lb) position. The Sys LED will rapidly blink green and a bell sound will be heard from the
speakers connected to the dS2 confirming the setup. The dS2 will then reboot to activate the new
position. During boot, the Sys LED will blink alternating RED-GREEN a few times to let the user know
alternate positions are being used.
Position
Definition
A
Center
B
Right
C
Right surround
D
Right back
E
Reserved
F
Left back
G
Left surround
H
Left
Position
Definition
A
Left & Right
B
Right & Right Surround*
C
Dual Mono Downmix
D
Center & Sub
E
Dual Sub
F
Left Back & Right Back
G
Left Surround & Right Surround
H
Left & Left Surround*
Alternate Position Definition
B
Right Surround and Right Back
H
Left Surround and Left Back