fOR yOUR PROTECTION, ALWAyS
DISCONNECT PUMP fROM ITS POWER SOURCE BEfORE
HANDLING
. Pumps supplied with a 3-prong grounded plug to
help protect you against the possibility of electrical shock.
DO NOT,
UNDER ANy CIRCUMSTANCES, REMOVE THE GROUND PIN.
the 3-prong plug
must
be inserted into a mating 3-prong grounded
receptacle. If the installation does not have such a receptacle, it must
be changed to the proper type, wired and grounded in accordance
with the National Electrical Code and all applicable local codes and
ordinances.
See FM0514 for simplex installations or FM0486 for duplex instal-
lations. Pumps
must
be installed in accordance with the National
Electrical Code and all applicable local codes and ordinances.
Pumps are not to be installed in locations classified as hazardous in ac
-
cordance with National Electrical Code, ANSI/NFPA 70.
Risk of electrical shock.
do not remove power supply
cord and strain relief or connect conduit directly to the pump.
Installation and checking of electrical circuits and hardware
should be performed by a qualified licensed electrician.
PUMP WIRING INSTRUCTIONS
SINGLE-PHASE INSTALLATION
to operate nonautomatic pumps automatically, a control panel or 15 amp
control switch (P/N 10-0034) must be added to the power circuit. Follow
the instructions provided with the panel or float switch to wire the system.
WIRING DIAGRAM fOR MODELS
115V, 1 PH, 60 HZ
MOTOR
017346 A
RUN
OVERLOAD
BLUE
RED
START
YELLOW
GREEN
BLACK
GREEN
L1
L2
WHITE
R
RELAY
1
5
2
CAPACITOR
START
CAPACITOR
RUN
(3)
YELLOW
(2)
RED
(1)
BLUE
BLACK
BLACK
WHITE