Limited Warranty

Manufacturer warrants, to the purchaser and subsequent owner during 
the warranty period, every new product to be free from defects in material 
and workmanship under normal use and service, when properly used 
and maintained, for a period of one year from date of purchase by the 
end user, or 18 months from date of original manufacture of the product, 
whichever comes fi rst.  Parts that fail within the warranty period, one 
year from date of purchase by the end user, or 18 months from the 
date of original manufacture of the product, whichever comes fi rst, that 
inspections determine to be defective in material or workmanship, will be 
repaired, replaced or remanufactured at Manufacturer's option, provided 
however, that by so doing we will not be obligated to replace an entire 
assembly, the entire mechanism or the complete unit.  No allowance 
will be made for shipping charges, damages, labor or other charges 
that may occur due to product failure, repair or replacement.

This warranty does not apply to and there shall be no warranty for 
any material or product that has been disassembled without prior 
approval of Manufacturer, subjected to misuse, misapplication, neglect, 
alteration, accident or act of God; that has not been installed, operated 
or maintained in accordance with Manufacturer's installation instructions; 
that has been exposed to outside substances including but not limited 
to the following:  sand, gravel, cement, mud, tar, hydrocarbons, 
hydrocarbon derivatives (oil, gasoline, solvents, etc.), or other abrasive 
or corrosive substances, wash towels or feminine sanitary products, 

etc. in all pumping applications.  The warranty set out in the paragraph 
above is in lieu of all other warranties expressed or implied; and we do 
not authorize any representative or other person to assume for us any 
other liability in connection with our products.

Contact Manufacturer at, 3649 Cane Run Road, Lou is ville, Ken tucky  
40211, Attention: Cus tom er Ser vice De part ment to obtain any need ed 
repair or re place ment of part(s) or additional in for ma tion pertaining to 
our warranty.

MANUFACTURER  EXPRESSLY  DIS CLAIMS  LI A BIL I TY  FOR 
SPE CIAL,  CON SE QUEN TIAL  OR  IN CI DEN TAL  DAM AG ES  OR 
BREACH OF EX PRESSED OR IMPLIED WARRANTY; AND ANY 
IMPLIED  WAR RAN TY  OF  FIT NESS  FOR  A  PAR TIC U LAR  PUR POSE 
AND OF MER CHANT ABIL I TY SHALL BE LIM IT ED TO THE DU RA TION 
OF THE EX PRESSED WAR RAN TY.

Some states do not allow limitations on the duration of an implied warranty, 
so the above limitation may not apply to you. Some states do not allow 
the exclusion or limitation of incidental or con se quen tial dam ag es, so 
the above lim i ta tion or exclusion may not apply to you.

This warranty gives you specifi c legal rights and you may also have 
other rights which vary from state to state.

Easy Do's & Don'ts for Installing a Sump Pump

 1. DO read thoroughly all installation material provided with the 

pump.

 2. DO inspect pump for any visible damage caused by shipping.  

Contact dealer if pump appears to be damaged.

 3. DO clean all debris from the sump.  Be sure that the pump will have 

a hard, fl at surface beneath it.  DO NOT install on sand, gravel or 
dirt.

 4. DO be sure that the sump is large enough to allow proper clearance 

for the level control switch(es) to operate properly.

 5. DO Always Disconnect Pump From Power Source Before 

Handling.

  

DO 

always connect to a separately protected and properly grounded 

circuit.

  

DO  NOT ever cut, splice, or damage power cord unless in a 
watertight junction box.

  

DO NOT carry or lift pump by its power cord.

  

DO NOT use an extension cord with a sump pump.

 6. DO NOT use a discharge pipe smaller than the pump discharge.

 7. DO NOT use a sump pump as a trench or excavation pump, or for 

pumping sewage, gasoline, or other hazardous liquids.

 8. DO test pump immediately after installation to be sure that the 

system is working properly.

 9. DO cover sump with an adequate sump cover.

 10.  DO review all applicable local and national codes and verify that 

the installation conforms to each of them.

 11.  DO consult manufacturer for clarifi cations or questions.

 12.  DO consider a two pump system with an alarm where an installation 

may become overloaded or primary pump failure would result in property 
damages.

 13.  DO consider a D.C. Backup System where a sump or de w a ter ing 

pump is necessary for the prevention of property damages from 
fl ooding due to A.C. power disruptions, mechanical or electrical 
problems or system over load ing.

  14.  DO inspect and test system for proper operations at least every 

three months.