Zoeller AquaNot Fit 508 Manual Download Page 2

TOTAL DYNAMIC HEAD FLOW 

PER MINUTE @ 12.1

 VOLTS

© Copyright 2019 Zoeller

®

 Co. All rights reserved.

502-778-2731  |  800-928-7867  |  3649 Cane Run Road  |  Louisville, KY  40211-1961  |  zoellerpumps.com

Shipping weight: 17 lbs. (7.7 kg)
NOTE:  Not recommended for installation with over 20' (6 m) Total Dynamic 

Head.

Performance chart based upon actual performance achieved with a 12 volt 
deep-cycle battery. Some manufacturers publish performance data based upon 
D.C. Pump testing according to Marine Industry standards which can reflect a 
performance of 40% - 80% higher than actual battery powered performance.

See FM3120 (Aquanot

®

 Fit 508) Installation Instructions.

Minimum pit size recommendation: 18" (46 cm) diameter X 22" (56 cm) 

deep. Minimum battery requirements: deep-cycle, size 27, 175 minute 

reserve capacity.

152944

WARRANTY

 

3 years from date of purchase. Battery warranty is 3 years.

BATTERY LIFE

 

The estimated life of a fully charged (175 minute reserve capacity) 
battery when the pump is operating continuously is approximately 
5.5 hours. However, most backup system pump operation is 
intermittent.The system will provide protection for extended periods 
of time dependent upon stop-start requirements and multiple 
battery arrangements.

PERFORMANCE DATA

  

Pump performance is based on the use of a fully charged 12 volt, 

(200-minute reserve capacity) deep-cycle battery with no deficiency 

and less than two years old.

AQUANOT

®

 BATTERY

 

 

• 

Size  31 “Wet” P/N 10-0761 (69 lbs. [31 kg]) (shipped via 
truckline only) 200 minute reserve capacity

• 

Size 27 “AGM” P/N 10-1450 (66 lbs. [30 kg]) 175-minute 
reserve capacity

TOTAL DYNAMIC HEAD/FLOW

PER MINUTE

EFFLUENT AND DEWATERING

22ft. (6.7m)

508

Shut-off Head:

MODEL

15

10

Feet

5

4.6

3.0

30

20

1.5

Meters

39

Gal.

76

114

148

Liters

20

6.1

6

23

FLOW PER MINUTE

LITERS  0

80

5

25

15

10

GALLONS

TOT

AL

 DYNAMIC HEAD

0

2

4

6

10

20

30

160

40

50

FEET

METERS 

20

8

PUMP PERFORMANCE CURVE

MODEL 508 @ 12.1 VOLTS

TOTAL DYNAMIC HEAD/FLOW

PER MINUTE

EFFLUENT AND DEWATERING

22ft. (6.7m)

508

Shut-off Head:

MODEL

15

10

Feet

5

4.6

3.0

30

20

1.5

Meters

39

Gal.

76

114

148

Liters

20

6.1

6

23

FLOW PER MINUTE

LITERS  0

80

5

25

15

10

GALLONS

TOT

AL

 DYNAMIC HEAD

0

2

4

6

10

20

30

160

40

50

FEET

METERS 

20

8

PUMP PERFORMANCE CURVE

MODEL 508 @ 12.1 VOLTS

All installation of controls, protection devices and wiring should be done by a qualified licensed electrician.  All electrical and safety codes should be 

followed including the most recent National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA).

CAUTION

SK3182

OUTLET

PRIMARY PUMP

1" MIN.

IMPORTANT: OFF LEVEL 

OF FLOAT ASSEMBLY 

MUST BE HIGHER THAN 

DC BACKUP PUMP INTAKE

DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP

BATTERY BOX

AQUANOT

®

 FIT CONTROLLER

OUTLET

CONTROLLER

HIGH WATER 

REED SENSOR

Reviews: