Summary of Contents for 912

Page 1: ...s pressurized and hot when operating Allow 2 1 2 hours after disconnecting before attempting service 9 Pump is not intended for potable water due to possible contamination by oil contained in the pump 10 Risk of electric shock These pumps have not been investigated for use in swimming pools and marine areas 11 Prop65 Warning for California residents Cancer and Reproductive Harm www P65Warning ca g...

Page 2: ...n derivatives oil gasoline solvents etc or other abrasive or corrosive substances wash towels or feminine sanitary products etc in all pumping applications The warranty set out in the paragraph above is in lieu of all other warranties expressed or implied and we do not authorize any representative or other person to assume for us any other liability in connection with our products Contact Manufact...

Page 3: ...float mechanism s 6 Use a discharge pipe equivalent in diameter to the pump s discharge 7 Basin must be in accordance with governing codes and specifications 8 Pump must be level and float mechanism s clear of sides of basin before starting pump 9 Basin must be clean and free of debris after installation 10 Gate valve shut off valve or ball valve to be supplied by installer and installed according...

Page 4: ... MATERIAL REQUIREMENTS MINIMUM 4 COMPACTED SUB BASE NO HUB STYLE CONNECTOR 4 INLET PIPE INSTALLED BY CONTRACTOR MINIMUM 4 BACKFILL MATERIAL SEE REQUIREMENTS BELOW ROTOMOLDED BASIN AS PER ENGINEER S SPECIFICATION FINISHED FLOOR VENT PIPE OFFSET FOR ILLUSTRATION PURPOSES DISCHARGE PIPE PUMP POWER CORD 1 4 3 4 1 2 1 SK3311 ...

Page 5: ...f electrical shock DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE GROUND PIN The 3 prong plug must be inserted into a mating 3 prong grounded receptacle If the installation does not have such a receptacle it must be changed to the proper type wired and grounded in accordance with the National Electrical Code and all applicable local codes and ordinances Risk of electrical shock Do not remove power supp...

Page 6: ...____________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ ____...

Page 7: ...____________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ ____...

Page 8: ...2020 Zoeller Co All rights reserved MAIL TO P O BOX 16347 Louisville KY 40256 0347 SHIP TO 3649 Cane Run Road Louisville KY 40211 1961 502 778 2731 1 800 928 PUMP FAX 502 774 3624 Visit our website zoellerpumps com ...