© Copyright 2003 Zoeller Co. All rights reserved.
TYPICAL SUMP/DEWATERING RECOMMENDED INSTALLATION
1) Electrical wiring must be in accordance with the National Electrical Code and all other appli-
cable state and local electrical requirements.
2) Install proper Zoeller Unicheck (combination check valve and union) preferably just above the
sump pit to allow easy removal of the pump for cleaning or repair.
3) Minimum pit size recommended is 18" diameter and 22" deep.
4) Locate Float Rod Guide about 6” below motor. Clamp guide to column with screw provided.
DO NOT OVERTIGHTEN!
Risk of flooding.
Be sure that float rod is vertical and can move up and down
freely. If float is angled or binds, pump may not start, allowing flooding to occur.
5) Screw float onto threaded end of rod. Threads on rod will cut threads into corrosion resistant
float.
6) Insert end of float rod up through eye of rod guide.
7) Slide one rod stop on float rod before passing rod through eye of pump switch. Slide 2nd rod
stop on rod after passing through eye of switch. Position 2nd rod stop flush with top of rod.
8) Position lower rod stop to within 8” of switch lever arm. With lower rod stop in this position,
pump will automatically cycle at approximately 2-1/2” off and 10-12” on. For faster cycling,
move lower rod stop closer to switch lever arm.
9) Thread pipe in discharge of pump. Use care not to cross thread or strip the threads. Use a
full-size discharge pipe.
10) Clean basin free of debris after installation.
11) Install blocks or bricks under pump to provide a settling basin.
12) Place pump in center of sump pit.
13) Securely tape or clamp power cord to discharge pipe clear of float mechanism.
14) Check for proper ON-OFF switch operation by running water into the sump pit.
15) All installations require a proper basin cover to prevent debris from falling into the basin and to
minimize accidental injury.
—CAUTION—
CHECK ROD AND FLOAT FOR FREE
SWITCH OPERATION TO INSURE
THAT PUMP WILL TURN ON AND OFF.
All installations must comply with all applicable electrical
and plumbing codes. Including, but not limited to, the Na-
tional Electric Code, local, regional and/or state plumbing
codes, etc.
SERVICE CHECKLIST TROUBLE SHOOTING CHART
UNPLUG PUMP BEFORE HANDLING PUMP OR PIPING
CONDITION
COMMON CAUSES
A. Unit will not start. 1. Check circuit protection.
2. Check electrical current supply to make sure it is the same as on the pump specification plate.
3. Check rod and float for free ON-OFF switch operation. Readjust rod stops or guide if necessary.
4. Check ON-OFF switch operation by running water into basin.
B. Unit starts or sounds like it is 1. Clear intake and discharge. Run to test operation.
running but will not pump. 2. Check to see that vertical lift of installation is within pump capacity (refer to pump capacity chart above).
3. Check impeller for proper rotation. (Clockwise when viewed from motor end).
C. Unit stops and starts excessively. 1. Install a proper Zoeller Unicheck to prevent back flow from piping.
2. Check dimensions of basin as listed on previous page, item 3.
If the above checklist does not uncover the problem, consult the factory - Do not attempt to service or otherwise disassemble pump.
SK2102
LIMITED WARRANTY
Zoeller Pump Company warrants, to the purchaser and subsequent owner during the
warranty period, every new Zoeller Pump Company product to be free from defects in
material and workmanship under normal use and service, when properly installed, used
and maintained, for a period of one year from date of installation or 18 months from date
of manufacturer, whichever comes first. Parts that fail, (within one year of installation or 18
months of manufacturer, whichever comes first) that inspections determine to be defective
in material or workmanship, will be repaired, replaced or remanufactured at Zoeller Pump
Company’s option, provided however, that by so doing we will not be obligated to replace
an entire assembly, the entire mechanism or the complete unit. No allowance will be made
for shipping charges, damages, labor or other charges that may occur due to product
failure, repair or replacement.
This warranty does not apply to any material that has been disassembled without prior ap-
proval of Zoeller Pump Company, subjected to misuse, misapplication, neglect, alteration,
accident or act of God; that has not been installed, operated or maintained in accordance with
Zoeller Pump Company installation instructions; that has been exposed to but not limited to
the following: sand, gravel, cement, mud, tar, hydrocarbons or hydrocarbon derivatives (oil,
gasoline, solvents, etc), wash towels or feminine sanitary products, etc. or other abrasive or
corrosive substances. This warranty is in lieu of all other warranties expressed or implied;
and we do not authorize any representative or other person to assume for us any other
liability in connection with our products.
Contact Zoeller Pump Company, 3649 Cane Run Road, Louisville, Kentucky 40211-1961,
Attention: Customer Service Department to obtain any needed repair or replacement of
part(s) or additional information pertaining to our warranty.
ZOELLER PUMP COMPANY EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL,
CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED OR
IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR
PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF
THE EXPRESSED WARRANTY.
Some states do not allow limitations on the duration of an implied warranty, so the above
limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental
or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have other rights which
vary from state to state.
�
��
�
�
��
��
��
��
�
�
�
�
�
�