Zoeller 64 HD Series Repair Manual Download Page 5

5

CAUTION

Block the lead wire opening in the motor housing (19) to prevent 

any parts from falling down into the motor.

 

4.  Cut shrink tubing (17) off wire connections. Remove 

hex nuts (18),  and screws (16) as necessary to break 

connects between lead wire assy. (7) and motor (29). 

Tag wires as disconnecting. Break connection between 

sensor wire assy. (11) and sensor wires. Remove hex 

head screw (19) and disconnect ground wire.

 

5.  If necessary, remove and replace wire connector (15).

 

6.  To replace sensor cord (11), remove screws (8), lock 

washers (9), and lead clamp (10). Pull sensor cord (11) 

from lead wire housing (12).

 

7.  To replace power cord (7), remove lead clamp cap (1), 

washer (2), and lock ring (3). Remove screws (4), lock 

washers (5) and lead clamp (6). Pull power cord (7) 

from lead wire housing (12).

 

8.  Remove seal ring (14) from lead wire housing and inspect 

for damage.

E.  When removing motor (29)...

 

1.   Complete Sections A, B, C and D.

 

2.  Remove the eight nuts (24), washers (25) and socket 

head screws (35) which secure the bearing housing 

(34) to the motor housing (20).

 

3.  Set motor assembly vertical on blocks and lift the motor 

housing (20) off the bearing housing (34) and motor 

assembly. Be careful to lift the motor housing (20) straight 

off, so as not to damage the motor (29).

 

4.  Remove the seal ring (26) from the bearing housing 

(34).

 

5.  Remove four long hex head through bolts that attach 

motor (29) to bearing housing (34) and note   which holes 

in bearing housing each one was removed from. Pry 

off top cap of motor and then remove stator and rotor 

separately. Be careful not to damage stator windings.

 

6.  Using a bearing puller, bearing against the inner race, 

remove the double row bearing (33). Replace the bearing 

if needed.

Note: 

 

The bearing should be cleaned with volatile mineral spirits 

and relubricated with proper lubricants immediately after 

cleaning. Never dry bearings with compressed air, and 

never spin unlubricated bearings.

F.  When removing sensor studs (32)...

 

1.  Complete Sections A through E5.

 

2.  Pull pin terminals of moisture sensor leads (32) loose 

from moisture sensors.

 

3.  Unscrew moisture sensors and remove.

ASSEMBLY PROCEDURES

Pumps are reassembled in reverse order of disassembly. The 

following suggestions are offered.

Note:    While pump is dismantled, all gaskets, seal rings 

and retaining rings should be checked for wear and 

deterioration. Replace all worn items. Insure that all parts 

are thoroughly cleaned before assembly.

A.  Installing fan (31) (Applies to installation of new motor 

only)...

 

1.  Press the fan (31) on the rotor shaft until seated against 

the rotor end ring. Note that the fan blades are bent away 

from the motor rotor.

B.  Installing sensor studs (37 or 39)...

 

(Before S/N 00605)

 

1.  Screw sensors (32) into bearing housing (34). Apply 34 

in. lbs. of torque.

 

2.  Push terminals of moisture sensor leads (32) onto moisture 

sensors (32).

C.  Installing motor (29)...

Note: Before installing the bearing (33), wipe the bearing seat on 

the shaft clean and coat the seat with oil to prevent galling of the 

shaft as the bearing (33) is pressed onto the shaft. A properly sized 

pressing sleeve should be used to install bearing (33), with pressure 

being applied to only the inner bearing race.

 

1.  Install the double row ball bearing (33) and the upper 

bearing on the shaft.

 

2.  Install the rotor/bearing assembly into the bearing housing 

(34) then lower stator down over rotor and position motor 

cap. Secure motor (29) to bearing housing (34) with four 

long hex head through bolts (supplied with motor).

CAUTION

Do not damage motor windings.

 

3.  Lightly oil and position the seal ring (26) around the pilot 

shoulder of bearing housing (34).

 

4.  Set the motor assembly vertical with the bearing housing 

(34) down, resting on blocks. Lower the motor housing 

(20) over the motor assembly, pulling the sensor wires 

(32) between the housing (20) and motor stator as the 

housing (20) is lowered.

 

5.  Pull the motor leads through the top of the housing (20).

 

6.  Seat the motor assembly in the motor housing (20) and 

secure with eight screws (35), nuts (24), and lock washers 

(25).

 

7.  Install the pipe plug (27) in the lower of the two holes in 

the side of the motor housing.

D.  Installing sensor cord (7) and power cord (11)...

 

1.  Apply light coating of oil on the molded part of both the 

power cord (7) and sensor cord (11), and install the two 

cords in the tapered bores of the wire housing (12).

 

2.  Slide the lead clamps (6 and 10) over the cords and secure 

to lead wire housing (11) with lock washers (5 and 9) and 

screws (4 and 8). Press lock ring (3) over power cord (7), 

and seat in lead clamp (6). Install washer (2) and cap (1) 

over clamp (6).

 

3.  Install the seal ring (14) on the lead wire housing (12).

 

4.  Connect lead wire terminals to motor lead terminals in the 

proper arrangement as per wiring diagram using screws 

(16) and nuts (18) and shrink tubing (17). Place shrink 

© Copyright 2019 Zoeller

®

 Co. All rights reserved.

Assembly Procedures

Disassembly Procedures, 

continued

Summary of Contents for 64 HD Series

Page 1: ...AND WARNINGS PRIOR TO PERFORMING ANY WORK ON THIS PUMP MAINTAIN ALL SAFETY DECALS CAUTION Short Term Storage PLEASE FURNISH THE FOLLOWING INFORMATION Model Number Part Number of Pump Serial Number Sys...

Page 2: ...Copyright 2019 Zoeller Co All rights reserved 1 2 3 4 5 6 7 13 5 15 20 21 22 24 25 26 17 18 29 30 8 9 10 11 12 27 32 34 35 37 38 39 36 40 41 27 42 43 44 45 46 48 47 49 50 51 16 17 18 16 14 28 23 19 5...

Page 3: ...Lock Washer 8 006404 24 Nut 8 001809 25 Lock Washer 8 007132 26 O Ring 1 2 007127 27 Pipe Plug 2 006460 28 Temperature Sensor 1 007190 29 Motor 1 SEE JOB FILE 30 Impeller Key 1 007408 31 Fan 1 008223...

Page 4: ...carefully pry the impeller 42 from the shaft 6 Remove the square key 30 from motor shaft Note Impellerhubservesaslowersealretainer Whenimpeller is removed seal spring will fall free C When removing ro...

Page 5: ...ll worn items Insure that all parts are thoroughly cleaned before assembly A Installing fan 31 Applies to installation of new motor only 1 Press the fan 31 on the rotor shaft until seated against the...

Page 6: ...its level when caps are installed G Final assembly 1 Fill the motor housing 20 with the same oil used to fill the seal retainer cavity in step E 8 above Fill until oil is level with the upper plug 20...

Page 7: ...AILURE PROBES PANEL INDUCTION CIRCUIT INTHE CONTROL LEADS MUST BE CONNECTEDTO SEAL FAILURE MOISTURE SENSOR THERMAL THETHERMAL SENSOR LEADS ARETO BE CONNECTED IN SERIES WITH STARTER COIL NOTE 1 SENSOR...

Page 8: ...Abrasive material chemical deteriorated impeller and pump housing If the above check list does not uncover the problem consult the factory Do not attempt to service or otherwise disassemble pump Servi...

Reviews: