RECOMMENDED INSTALLATION FOR ALL APPLICATIONS

  (1)   Electrical  wiring  and  protection  must  be  in  accordance  with 

National Electrical Code and any other applicable state and 

local electrical requirements. 

  (2)   Install proper Zoeller unicheck (combination union and check 

valve), preferably just above the basin to allow easy removal of 

the pump for cleaning or repair. See (4) below. 

  (3)   All installations require a basin cover to prevent debris from 

falling into the basin and to prevent accidental injury. 

  (4)   When a Unicheck is installed, drill a 

3

/

16

" (5 mm) dia. hole in 

the discharge pipe even with the top of the pump. 

NOTE: THE 

HOLE MUST ALSO BE BELOW THE BASIN COVER AND 

CLEANED PERIODICALLY. 

Water stream will be visible from 

this hole during pump run periods.

  (5)   Securely tape or clamp power cord to discharge pipe, clear of 

the float mechanism(s). 

  (6)  Use full-size discharge pipe. 
  (7)   Basin  must  be  in  accordance  with  applicable  codes  and 

 

specifications.

  (8)   Pump must be level and float mechanism(s) clear of sides of 

basin before starting pump.     

  (9)  Basin must be clean and free of debris after installation.
 (10)   Gate valve or ball valve to be supplied by installer and installed 

 

according to any and all codes.

 (11)  Gas tight seals required to contain gases and odors.
 (12)     Vent  gases  and  odors  to  the  atmosphere  through  vent  pipe 

(Sewage & Dewatering only).

 (13)    Install Zoeller Pump Stand  (10-2421) under pump to provide a 

 

  settling basin. (Effluent & Dewatering only.)

TYPICAL DEWATERING INSTALLATION

SK292

TURN

ON

TURN

OFF

1

2

3

7

9

14

8

6

4

5

10

12

13

4” (10 cm) OF GRAVEL

    MINIMUM

(457 mm X 610 mm)

 18"x24" BASIN

 LARGER DEPTHS
    MAY BE 
   REQUIRED.

MAIL TO:

  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO:

  3649 Cane Run Road • Louisville, KY  40211-1961

(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624

Your Peace of Mind is Our Top Priority

 

®

®

visit our web site:

www.zoeller.com

See FM0531, FM0732 & FM1420 for 

alarms, controls & junction boxes.

All installations must comply with all applicable electrical and plumbing codes, including,  but not limited to, National Electrical Code, local, regional, and/or state plumbing 

codes, etc. Not intended for use in hazardous locations.