1.  To reduce the risk of electrical shock, a properly grounded 

receptacle of grounding type must be installed and protected 

by a ground fault circuit interrupter (GFCI) and in accordance 

with national electrical code and local codes.

2.  Use an appropriate, gauged, extension so as not to create a 

voltage drop beyond the operating parameters of the pump.  

Check for cracks in the insulation, exposed wiring or electrical 

taped splices.  Do not use an extension cord as it could cause 

a safety hazard.

3.  Testing for Ground. As a safety measure, each electrical outlet 

should be checked for ground using an Underwriters Laboratory 

Listed circuit analyzer which will indicate if the power, neutral 

and ground wires are correctly connected to your outlet. If they 

are not, call a qualified electrician.

4.  For electrical safety, it is recommended that a GFCI be installed.
5. 

FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP 

FROM ITS POWER SOURCE BEFORE HANDLING. 

Single 

phase pumps are supplied with a 3-prong grounded plug to 

help protect against the possibility of electrical shock. 

DO NOT, 

UNDER ANY CIRCUMSTANCES, REMOVE THE GROUND 

PIN

. To reduce the risk of electrical shock, a properly grounded 

receptacle of grounding type must be installed and protected 

by a ground fault circuit interrupter (GFCI) in accordance with 

national electrical code and local codes.

6.  Installation and checking of electrical circuits and hardware 

should only be performed by a qualified, licensed electrician.

7.  Risk of electric shock. These pumps have not been investigated 

for use in swimming pool and marine areas.

8.  According to the state of California (Prop 65), this product 

contains chemicals known to the state of California to cause 

cancer and birth defects or other reproductive harm.

NOTICE TO INSTALLER:  Instructions must remain with installation.

FM2820

0517

Supersedes

0815

MODEL 118

FLOOD KIT

PREINSTALLATION CHECKLIST

1.  Inspect your unit. Occasionally, products are damaged during shipment. If the unit is damaged, contact  your dealer before using. 

DO NOT

 remove the test plug or the motor housing.

 

2.  Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should 

be retained for future reference. 

1.  Check to be sure your power source is adequate for handling 

the voltage requirements of the motor, as indicated on the pump 

or basin plate.

2.  Make sure the pump electrical supply circuit is equipped with 

fuses or circuit breakers of proper capacity. A separate branch 

circuit is recommended, sized according to the National Electrical 

Code for the current shown on the pump name plate.

3.

 

Pump should be checked frequently for debris and/or build-up 

which may interfere with the float “on” or “off” position. Repair 

and service should be performed by a Zoeller Pump Company 

Authorized Service Station only.

4.  Dewatering pumps are not designed or intended for handling 

raw sewage.

5.  Maximum operating temperature for AquaMate submersible 

pump must not exceed 110°F  (43°C).

SEE BELOW FOR LIST OF WARNINGS

CAUTION

SEE BELOW FOR LIST OF CAUTIONS

REFER TO WARRANTY ON PAGE 2.

NOTE:

  Pumps  with  the  “UL”  mark  and  pumps  with  the  “US” 

mark are tested to UL Standard UL778. CSA Certified pumps 

are certified to CSA Standard C22.2 No. 108.

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO:  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO:  3649 Cane Run Road  • Louisville, KY  40211-1961

TEL: (502) 778-2731 • 1 (800) 928-PUMP • FAX: (502) 774-3624

visit our web site:

www.zoellerpumps.com

Your Peace of Mind is Our Top Priority

 

®

Summary of Contents for 118

Page 1: ...ns chemicals known to the state of California to cause cancer and birth defects or other reproductive harm NOTICE TO INSTALLER Instructions must remain with installation FM2820 0517 Supersedes 0815 MODEL 118 FLOOD KIT PREINSTALLATION CHECKLIST 1 Inspect your unit Occasionally products are damaged during shipment If the unit is damaged contact your dealer before using DO NOT remove the test plug or...

Page 2: ... theabovelimitationmaynotapplytoyou Somestatesdonotallowtheexclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state LIMITED WARRANTY Manufacturerwarrants tothepurchaserandsubsequentownerduringthewarranty period every new pro...

Page 3: ...13436 SK2970A SK2970 COMPONENTS ATTACH ROPETO HANDLE ROPE SUPPLIED BY OTHERS Securing Rope to Handle HOSE DISCHARGE KIT CRAWL SPACE BASIN COVER MOUNTING BRACKET PUMP S S HANDLE CLEVIS PIN HAIRPIN COTTER PIN SPACER FLATWASHER HOSE CLAMP HOOK AND LOOP STRAP SERVICE PARTS Hose Discharge Kit 1010 0117 Pump M76 76 0016 Copyright 2017 Zoeller Co All rights reserved ...

Page 4: ...al overload open Contact a Zoeller Authorized Service Station Bound impeller Shorted motor or wiring Damaged float Bound float assembly Check for debris around float B PUMP TRIPS OVERLOAD OR BLOWS FUSE Incorrect voltage Have a qualified electrician check circuit Bound impeller Contact a Zoeller Authorized Service Station Shorted motor C PUMP STARTS AND STOPS TOO OFTEN Short cycling Check for debri...

Page 5: ...0S MODELO 118 JUEGO CONTRA INUNDACIONES LISTA DE VERIFICACIÓN DE PRE INSTALACIÓN 1 Inspeccione todos materiales Ocasionalmente los productos se dañan durante el envío Si la unidad está dañada comuníquese con su vendedor antes de usarla NO quite los tapones de prueba de la bomba 2 Lea cuidadosamente toda la literatura provista para familiarizarse con los detalles específicos relacionados con la ins...

Page 6: ...ARA UN FIN PARTICULAR Y DE COMERCIALIZACIÓN SE LIMITARÁ A LA DURACIÓN DE LA GARANTÍA EXPRESA Algunosestadosnopermitenlimitacionesenladuracióndeunagarantíaimplícita de forma que la limitación anterior podría no aplicar a usted Algunos estados no permiten la exclusión o limitación de daños incidentales o emergentes de forma que la limitación o exclusión anterior podría no aplicar a usted Esta garant...

Page 7: ...SOGA CON LA MANIJA LA SOGA ES SUMINISTRADA POR TERCEROS Asegure soga a la manija CORREA DE BUCLE Y GANCHO CONTENEDOR DE CÁMARA SANITARIA CUBIERTA SOPORTE DE MONTAJE BOMBA MANIJA DE ACERO INOXIDABLE PASADOR DE GRILLETE HORQUILLA SEPARADOR ARANDELA PLANA ABRAZADERA DE MANGUERA PIEZAS DE SERVICIO Juego de descarga de mangueras 1010 0117 Bomba M76 76 0016 Copyright 2017 Zoeller Co Todos los derechos r...

Page 8: ...ascado Revise si hay escombros alrededor del flotador B EL MOTOR SE SOBRECALIENTA Y ACTIVA LA PROTECCIÓN CONTRA SOBRECARGA O DESCONECTA EL FUSIBLE Voltaje incorrecto Pídale a un electricista calificado que revise el circuito Impulsor atascado Comuníquese con un centro de servicio autorizado de Zoeller Motor en corto C LA BOMBA SE ENCIENDA Y SE APAGA MUY A MENUDO Ciclos muy cortos Revisesihayescomb...

Page 9: ...AVANT L INSTALLATION 1 Inspecter tout matériaux De temps en temps la pompe est endommagée en cours d expédition Si la pompe est endommagée contacter le distributeur avant de l utiliser NE PAS enlever les bouchons test du la pompe 2 Il faut lire attentivement tous les documents fournis pour se familiariser avec les détails spécifiques de l installation et de l utilisation Il faut conserver ces docu...

Page 10: ...FIQUE OU DE COMMERCIALITÉ EST LIMITÉE À LA DURÉE DE LA GARANTIE EXPRESSE Certaines provinces ne permettent pas les limitations de la durée de la garantie implicite et il est possible que cette limitation ne s applique pas Certaines provinces ne permettent pas l exclusion ou la limitation des dégâts secondaires ou indirects et il est possible que cette limitation ou exclusion ne s applique pas Cett...

Page 11: ...IGNÉE CORDE FOURNIE PAR D AUTRES Fixer la corde à la poignée KIT DETUYAU D ÉVACUATION VIDE SANITAIRES DE LA CUVE COUVERCLE SUPPORT DE FIXATION POMPE POIGNÉE EN ACIER INOXYDABLE GOUPILLE DE BLOCAGE GOUPILLE EN ÉPINGLE À CHEVEUX ENTRETOISE RONDELLE PLATE COLLIER DU FLEXIBLE CROCHET ET SANGLE POUR BOUCLE PIECES D ENTRETIEN Kit de tuyau d évacuation 1010 0117 Pompe M76 76 0016 Copyright 2017 Zoeller C...

Page 12: ...Flotteur endommagé Flotteur bloqué Rechercher des débris autour du flotteur B LE MOTEUR SURCHAUFFE ET DÉCLENCHE LE DISJONCTEUR OU LA SÉCURITÉ THERMIQUE Mauvaise tension Demander à un électricien qualifié de vérifier le circuit Impulseur engorgé Contacter un Centre d entretien autorisé Zoeller Moteur en court circuit C LA POMPE SE MET EN MARCHE ET S ARRÊTE TROP FRÉQUEM MENT Cycle court Rechercher d...

Reviews: