9.   Apply pipe tape (not included) to all threaded 

connections, and a 2-step PVC glue system (not 

included) to non-threaded connections.

9

Trap

Assembly

10. Place the basin lid (E)/trap assembly from step 7 on 

top of the basin (B), making sure the foam gasket (H) is 

firmly in place. Screw in the 8 bolts removed in step 3.

10

Cord

Seal

Opening

11.  Pull excess power cord through the cord seal (F) 

opening and reinstall the cord seal (F). Make sure the 

o-ring is seated in the seal before reinstallation.

11

E

B

F

H

Summary of Contents for 1104-0082

Page 1: ...in basin Zoeller is a registered trademark of Zoeller Co All Rights Reserved Serial Number Purchase Date Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 584 8089 7 30 a m 5 00 p m EST Monday Friday ATTACH YOUR RECEIPT HERE ...

Page 2: ...h of the pump s power supply cord DO NOT USE AN EXTENSION CORD ELECTRICAL SHOCK ALERT Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occupational Safety and Health Act OSHA ELECTRICAL SHOCK ALERT Do not kink power cable and never allow the cable to come in contact with oil grease hot surfaces chemicals or sharp objects Replace damaged or worn wirin...

Page 3: ... pumps must not exceed 110 F 43 C PRODUCT DAMAGE MAY RESULT Do not use an automatic plumbing vent device such as a Pro Vent Some states require this product to be installed by a licensed plumber Part Description Quantity A Pre Assembled Pump System Includes B through H 1 B Basin 1 C Pump 1 D Check Valve 1 E Basin Lid 1 F Cord Seal 1 G Inlet Cap and Seal 1 H Foam Gasket 1 PACKAGE CONTENTS A E F D C...

Page 4: ...VC glue system primer and sealer Parts Required For Standard Assembly not included 2 in slip by NPT coupling 1 1 2 in slip by NPT coupling drain pipe compression fitting for 1 1 4 in drain pipe PVC pipe and fittings as required to complete installation additional check valve as required by codes 1 Wet bar sink pump GENERAL PUMP USES 2 Laundry tray pump Laundry Tray Sink Washer Vent Pipe Inlet Pipe...

Page 5: ...scharge Pipe 3 3 Softener discharge pump Inlet Pipe Vent Pipe Discharge Pipe 4 4 Dehumidifier pump INSTALLATION INSTRUCTIONS Vent Opening 1 Thread 2 in coupling not included into the vent opening on the top of the pre assembled pump system 1 ...

Page 6: ... rigid 2 in vent pipe not included to the vent pipe coupling according to local regional and state codes 4 Attach rigid 1 1 2 in discharge pipe not included to the discharge pipe coupling according to local regional and state codes Plumb into existing drain pipe per local regional and state codes Use check valve not included as required by codes ...

Page 7: ... for standard installation pre assembled pump system can be installed directly under a sink using an internal trap not included NOTE Check local and state codes before using the internal trap option 4 in min Internal trap 1 4 in min Plus 4 1 2 in Tailpipe 2 Place the pre assembled pump system beneath the sink and measure the distance between the sink inlet and the basin lid Minimum distance is 4 i...

Page 8: ...eal F and basin lid E 4 5 5 Remove black inlet cap and o ring G from basin lid E and screw it onto the inlet opening on the side of the basin B Side Inlet Opening B 3 Cut a tailpipe not included to the total pipe length in step 2 X 4 in min 4 1 2 in Tailpipe Length 3 E F E G G ...

Page 9: ...losest to the pump float and the trap discharge is against the wall of the basin B Trap Inlet Internal Trap Discharge Inside Basin Pre Assembled Pump System Top View Inlet Opening in Lid Cord Opening in Lid Vent Opening in Lid Discharge Opening in Lid Pump Discharge Pump Float 7 Thread 1 1 4 in compression fitting not included onto the tailpipe from step 3 Insert the tailpipe into the inlet openin...

Page 10: ...y 10 Place the basin lid E trap assembly from step 7 on top of the basin B making sure the foam gasket H is firmly in place Screw in the 8 bolts removed in step 3 10 Cord Seal Opening 11 Pull excess power cord through the cord seal F opening and reinstall the cord seal F Make sure the o ring is seated in the seal before reinstallation 11 E B F H ...

Page 11: ... opening on the top of the basin B 12 B 14 14 Attach rigid 2 in vent pipe not included to the vent pipe coupling according to local regional and state codes 13 Thread 1 1 2 in coupling not included into the discharge opening at the top of the basin B 13 B ...

Page 12: ...cording to local regional and state codes Plumb into existing drain pipe per local regional and state codes Use additional check valve not included as required by codes 16 Connect inlet pipe not included to appliance according to local regional and state codes Discharge Pipe Vent Pipe Inlet Pipe ...

Page 13: ...gional and state codes Use additional check valve not included as required by codes 2 Connect pump power supply cord to a receptacle protected by a ground fault circuit interrupter GFCI 3 Fill the basin B with water to check operation The pump will start when the water level has reached the switch on level Discharge Pipe Vent Pipe Inlet Pipe Main Waste Line GFCI Protected Receptacle On Level B ...

Page 14: ...ll check valve 2 Switch is defective 2 Replace switch 3 Check valve not functioning properly or leaking 3 Be sure check valve is installed and operating properly Replace check valve if necessary 4 Float is too tight on float rod 4 Clean debris build up off float rod 5 Overload is open 5 Allow motor to cool and overload to reset Pump will not shut off 1 Switch is defective 1 Replace switch 2 Switch...

Page 15: ... 5 38 10 30 15 14 SPECIFICATIONS Problem Possible Cause Corrective Action Capacity or flow drops after a period of use 1 Clogged inlet or discharge pipe 1 Clean all piping 2 Check valve clogged or defective 2 Be sure check valve is installed and operating properly Replace check valve if necessary 3 Abrasive material or chemicals damaged impeller or pump housing 3 Remove base and inspect TROUBLESHO...

Page 16: ...Inspect and test system for proper operation at least every three months 1 Remove any build up of debris from the switch or float and check to be sure it moves freely Debris on Float 1 Debris in Basin 2 2 Remove any debris from the basin that could interfere with the operation of the switch ...

Page 17: ...the unit is used for purposes other than for what it was designed and manufactured RETURN OF WARRANTED COMPONENTS Any item to be repaired or replaced under this warranty must be returned to the manufacturer at such place as the manufacturer may designate freight prepaid THE WARRANTY PROVIDED HEREIN IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES AND MAY NOT BE EXTENDED OR MODIFIED BY ANYONE ANY IMPLIED...

Page 18: ...or replacement parts call our customer service department at 1 800 584 8089 8 a m 8 p m EST Monday Friday E F D C B PART DESCRIPTION PART NO B Basin 013017 C Pump 152289A D Check Valve 019768 E Basin Lid 013018 F Cord Seal 006018 ...

Reviews: