2” INLET / HIGH HEAD 

DRAIN PUMP SYSTEMS 

MODELS 105-0010, 135-0005 

 

INSTALLATION INSTRUCTIONS 

PREINSTALLATION CHECKLIST 

FM2170

0114

Supersedes

0703

Notice to Installer:  Instructions must remain with installation.

MODEL:_______________________

DATE CODE:  __________________

DATE INSTALLED:   _____________

1.   Inspect your unit. Occasionally, products are damaged during shipment. If the unit is damaged, contact  your dealer before using.  

DO NOT

 remove the test plugs from the pump. 

2.   Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials 

should be retained for future reference. 

1. 

To reduce the risk of electrical shock,

 a properly grounded 

receptacle of grounding type must be installed and protected 

by a ground fault circuit interrupter (GFCI) and in accordance 

with National Electrical Code and local codes. 

  (SEE WARNING BELOW)

 

2. 

Make certain that the receptacle is within the reach of the 

pump’s power supply cord.

 DO NOT USE AN EXTENSION 

CORD.  Extension cords that are too long or too light do not 

deliver sufficient voltage to the pump motor. But more impor

-

tant, they could present a safety hazard if the insulation were 

to become damaged or the connection end were to fall into the 

sump.

3. 

Testing for Ground.

 As a safety measure, each electrical outlet 

should be checked for ground using an Underwriters Laboratory 

Listed circuit analyzer which will indicate if the power, neutral 

and ground wires are correctly connected to your outlet. If they 

are not, call a qualified electrician.

4. 

For Added Safety.

 Pump must be connected to a 3-prong 

grounded outlet interrupter device (ground fault circuit inter-

rupter).

5.

  FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP 

FROM ITS POWER SOURCE BEFORE HANDLING. 

 Single 

phase pumps are supplied with a 3-prong grounded plug to help 

protect you against the possibility of electrical shock. 

 DO NOT, 

UNDER ANY CIRCUMSTANCES, REMOVE THE GROUND 

PIN

.  To reduce the risk of electrical shock, a properly grounded 

receptacle of grounding type must be installed and protected 

by a ground fault circuit interrupter (GFCI) in accordance with 

national electrical code and local codes.

6.  Installation and checking of electrical circuits and hardware 

should only be performed by a qualified licensed electrician. 

7.  Risk of electric shock - These pumps have not been investigated 

for use in swimming pool areas.

8.  According to the state of California (Prop. 65), this product 

contains chemicals known to the state of California to cause 

cancer and birth defects or other reproductive harm.

1.  Check to be sure your power source is adequate for handling 

the voltage requirements of the motor, as indicated on the pump 

or basin plate. 

2.  Make sure the pump electrical supply circuit is equipped with 

fuses or circuit breakers of proper capacity. A separate branch 

circuit is recommended, sized according to the National Electri-

cal Code for the current shown on the pump name plate. 

3.  All plumbing (discharge and vent lines) must be installed to meet 

local codes. Unit must be vented. 

DO NOT USE AN AUTOMATIC 

PLUMBING VENT DEVICE SIMILAR TO A “PRO-VENT”

Some states require this product to be installed by a licensed 

plumber.

4.  Repair and service should be performed by Zoeller Pump 

Company Authorized Service Station only.

5.  CHECK VALVE MUST BE USED TO REDUCE UNNECESSARY 

CYCLING OF PUMP.

6.  Dewatering pumps are not designed or intended for handling 

raw sewage. 

7.  Maximum operating temperature for 105-0010 and 135-0005 

Drain Pumps must not exceed 130° F (54° C).

8.  For health reasons, do not unplug, turn off, or disable pump 

and use pump tank system as a way to fill up a sink or laundry 

tray, etc.

SEE BELOW FOR LIST OF WARNINGS

CAUTION

SEE BELOW FOR LIST OF CAUTIONS

REFER TO WARRANTY ON PAGE 2.

NOTE: Pumps with the “UL” mark and pumps with the “US” mark 

are tested to UL Standard UL778. CSA Certified pumps are 

certified to CSA Standard C22.2 No. 108.

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO:  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO:  3649 Cane Run Road  • Louisville, KY  40211-1961

(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624

visit our web site:

www.zoeller.com

®

Your Peace of Mind is Our Top Priority

 

®

Summary of Contents for 105-0010

Page 1: ...grounded receptacle of grounding type must be installed and protected by a ground fault circuit interrupter GFCI in accordance with national electrical code and local codes 6 Installation and checking of electrical circuits and hardware should only be performed by a qualified licensed electrician 7 Riskofelectricshock Thesepumpshavenotbeeninvestigated for use in swimming pool areas 8 According to ...

Page 2: ...ot allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Limited Warranty ELECTRICAL PRECAUTIONS Before servicing a pump always shut off the main power breaker and then unplug the pump mak ing sure you are not s...

Page 3: ... 6 30 9 1 016301A PUMP PERFORMANCE CURVE MODELS 105 135 0 4 8 12 16 20 24 70 60 50 40 30 20 10 0 5 2 4 6 8 10 35 30 25 20 15 10 FLOW PER MINUTE GALLONS LITERS TOTAL DYNAMIC HEAD 40 12 METERS FEET 105 135 TOTAL DYNAMIC HEAD FLOW PER MINUTE EFFLUENT AND DEWATERING 1 DO read all installation material included with the pump 2 DO inspect unit for any visible damage caused by ship ping Contact dealer if...

Page 4: ...actual configuration will vary depending on your cabinet and sink configuration STEP 2 Install the Discharge Pipe onto the Pump All Models Figure 2 1 SK2367 SK2002B BE SURE THAT WEEPHOLE IS NOT DIRECTED TOWARD THE FLOAT Water stream will be visible from this hole during pump run periods Note Model 105 shown PIPING SHOWN ONLY FOR CLARITY DISCHARGE PIPE PUMP DISCHARGE WEEP HOLE IMPORTANT ...

Page 5: ...n in Figures 3 1 3 3 3 2 Attach float to discharge pipe as shown in Figure 3 4 Figure 3 1 SK2368 Figure 3 2 Figure 3 3 Figure 3 4 SK2370 SK2371 SK2372 BOTTOM VIEW ATTACH BRACKET TO SWITCH USING THE SCREWS PROVIDED 1 LOCKING PIN MUST BE INSTALLED UNDER FLOAT ROD IN THIS LOCATION 2 3 4 5 SLIDE FLOAT STOP TO THE TOP OF THE FLOAT ROD 9 1 2 GASKET SEAL DETAIL OVERLAP DETAIL 1 4 GASKET SEAL MUST BE PLAC...

Page 6: ...seal into the lid at this time 5 2 Place model 105 drain pump into basin per Figure 5 1 Place Model 135 drain pump into basin per Figure 5 2 Ensure the float switch is positioned for up and down movement without interference from the power cord or the tank wall 5 3 Slip open end of short discharge pipe into 1 slip fitting in lid 5 4 Adjust lid and pump so that keyed notches on lid and basin are al...

Page 7: ... thru Current Item Description QTY Part No Part No Part No 1 Drain Pump 1 105 0010 135 0005 135 0010 2 Replacement pump M53 1 007917 N A N A Replacement pump WM 152 N A 015480 N A Replacement pump WD 152 N A N A 152990 3 Basin Cover Seal 1 004597 004597 004597 4 Discharge Tube 1 004400 013732 013732 5 Hardware Pack 1 007725 007725 007725 6 Basin Seal 1 006302 006302 006302 7 Check valve 1 30 0181 ...

Page 8: ...P O BOX 16347 Louisville KY 40256 0347 SHIP TO 3649 Cane Run Road Louisville KY 40211 1961 502 778 2731 1 800 928 PUMP FAX 502 774 3624 Your Peace of Mind is Our Top Priority visit our web site www zoeller com ...

Reviews: