background image

PACKAGE CONTENTS

2

SAFETY INFORMATION

DESCRIPTION

QUANTITY

Pump

1

Adapter

1

Please read and understand this entire manual before attempting to assemble, operate, or install 

the product.

•  NOTE:

 Pumps with the “UL” Mark and pumps with the “US” mark are tested to UL Standard 

UL778. CSA certifi ed pumps are certifi ed to CSA Standard C22.2 No. 108. (CUS.)

DANGER

•  FIRE/EXPLOSION HAZARD.

Pump only clear water. Do not pump fl ammable or explosive fl uids such as gasoline, fuel oil, 

kerosene, etc. Do not use in a fl ammable and/or explosive atmosphere. Failure to follow these 

warnings could result in death or serious injury and/or property damage.

•  RISK OF ELECTRIC SHOCK.

 

These pumps have not been investigated for use in swimming pool areas.

•  RISK OF ELECTRIC SHOCK. 

Always disconnect power source before attempting to install, service, or maintain the pump. 

Never handle a pump with wet hands or when standing on wet or damp surface or in water. Fatal 

electrical shock could occur.

PERFORMANCE

ITEM

NUMBER

HP

AMPS

GALLONS PER HOUR AT DISCHARGE HEIGHT 

ABOVE PUMPING LEVEL

0 FT.

5 FT.

10 FT.

15 FT.

20 FT.

1043

1/3

3.0

2400

2100

1680

1380

600

Summary of Contents for 1043-0006Q

Page 1: ...f Zoeller Co All Rights Reserved Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 584 8089 7 30 a m 5 00 p m EST Monday Friday ATTACH YO...

Page 2: ...l oil kerosene etc Do not use in a flammable and or explosive atmosphere Failure to follow these warnings could result in death or serious injury and or property damage RISK OF ELECTRIC SHOCK These pu...

Page 3: ...oil and chemicals Avoid kinking the cord Replace or repair damaged or worn cords immediately CHEMICAL ALERT Prop65 Warning for California residents WARNING Cancer and Reproductive Harm www P65Warnings...

Page 4: ...red for Assembly PREPARATION INSTALLATION INSTRUCTIONS 1 Attach garden hose adapter to the pump discharge and then connect garden hose to adapter B DO NOT OVER TIGHTEN THE GARDEN HOSE OR HOSE ADAPTER...

Page 5: ...e pump sooner unplug the pump for a few seconds and plug it back in NOTE This pump does not contain a water level sensor but will automatically shut itself off when water level drops to 1 8 in A built...

Page 6: ...hat you are not standing in water Unplug pump Remove debris 1 2 If pump clogs unplug the pump from the power supply Attach one end of a garden hose to a spigot and the other end to pump discharge Turn...

Page 7: ...utlet 2 Restricted discharge hose 2 Increase hose diameter to 3 4 in 3 Pump damaged 3 Replace pump 4 Plugged or kinked discharge 4 Clean and straighten hose Flow rate is low 1 Hose kinked 1 Straighten...

Page 8: ...it is used for purposes other than for what it was designed and manufactured RETURN OF WARRANTED COMPONENTS Any item to be repaired or replaced under this warranty must be returned to the manufacturer...