6
2.4.4 Connecting options
Heating priority:
• Function: control system to run the filtration pump (per cycle of 5 minutes minimum every 220 minutes (modifiable, see
§2.3), with the filtration running if the pool temperature is lower than the set point temperature).
• To connect, connect the filtration timer to terminals 1 and 2, add a shunt in between terminals 3 and 4.
Remote control module:
• The unit has the option of remote line control function.
• Function: to control the heat pump operation from a distance.
• For connection see the remote control module manual.
3. Use
3.1 Presentation of the regulation
Symbol
Meaning
Fixed
Flashing
Off
Water flow
Water flow correct
Water flow too low or absent
/
Heating
Active
Starting up
Inactive
Ambient air temperature
Sufficient
Insufficient
/
Priority heating connected Priority heating connected
and heating request
Priority heating connected
but no heating request
Priority heating
not connected
Fault
Fault detected, see §5
External pump or heating
priority connected, running
to reach set point but water
flow too low or missing
No fault
«On/Off» button
Pool water temperature reading and parameter setting button
Value adjustment buttons
3.2 Checks before commissioning
• Correct tightening of hydraulic fittings,
• Good stability (appliance level and vertical),
• The electric power supply cable must be isolated from all sharp or hot elements that could damage or crush it.
3.3 Starting up the appliance
• Start up water circulation and adjust the valves (see §2.3),
• Connect the heat pump electricity supply:
(programme version n° different depending on the model) then
,
• Powering on: press for 2 seconds:
then
by default the screen displays the set point temperature,
• The appliance starts after a timer that can last up to 5 minutes,
• Set the required temperature (so-called «set point»): when the heat pump is running, press
or
to set the
temperature.
• Water temperature reading: when water is flowing through the heat pump, press
:
flashes 10
seconds then the fixed temperature set point is displayed,
A1-A2 : power for the power switch coil of the filtration pump
B : Filtration timer
C : power switch (three-pole or two-pole), powering the filtration pump motor
D : independent connexion cable for the “heating priority” function
E : heat pump terminal box
F : fuse