Page 3
AquaPure® and PureLink
TM
Tri-Sensor Adapter Installation Kit
|
Zodiac®
AKC13 Front Board
Tri-Sensor
Connector
Tri-Sensor
Cable
Tri-Sensor Adapter
For all PureLink systems with AKC13
front board, an additional cable
assembly P/N R0538600, is required.
Figure 4. Installation of the Tri-Sensor Adapter on
an AKC13 Front Board
4.
For PureLink systems only:
For all PureLink systems with AKC13 front
board, an additional cable assembly part number
R0538600 is required due to the limited space
between the AKC13 front board and the power
center.
CAUTION
Do not attempt to force the installation of the tri-sensor
adapter directly into the AKC13 front board. The cable
assembly P/N R0538600 must be used for proper operation
and to avoid damaged to the tri-sensor board.
a. Connect the cable assembly P/N R0538600
to the tri-sensor adapter and the tri-sensor
connector of the AKC13 front board.
See Figure 4.
b. Connect the tri-sensor cable 8-pin connector
into the 8-pin male connector on the tri-sensor
adapter.
5.
For other systems:
a. Connect the tri-sensor cable 8-pin connector
into the 8-pin male connector on the tri-sensor
adapter.
b. Connect the 8-pin female connector of sensor
adapter into the tri-sensor connector on the
AKC13 front board.
7. Turn ON power to the AquaPure/PureLink systems
and circulation pump.
D. Calibrate the Tri-Sensor Adapter
When installing a tri-sensor adapter to an existing
AquaPure/PureLink systems or when replacing an
existing tri-sensor adapter, the tri-sensor adapter must
be calibrated as follows:
1. Install the tri-sensor adapter as explained in
Sections A and B of this document.
2. Make sure to turn ON power to AquaPure/PureLink
systems and circulation pump.
3. Wait a minimum of four (4) minutes to stabilize the
temperature readings of the tri-sensor.
4. On the tri-sensor adapter, press and hold the
calibration button for five seconds until the "Flow"
indicator is illuminated. See Figure 5.
5. The sensor is now properly installed.
Calibration
Button
Flow Indicator Light
Jumper
Tri-Sensor Adapter
Figure 5. Components of the Tri-Sensor Adapter