Zodiac R0537600 Instructions Download Page 3

Page 3

AquaPure® and PureLink

TM

 Tri-Sensor Adapter Installation Kit   

|

   Zodiac® 

AKC13 Front Board

Tri-Sensor

Connector

Tri-Sensor 

Cable 

Tri-Sensor Adapter

For all PureLink systems with AKC13 

front board, an additional cable 

assembly P/N R0538600, is required.

Figure 4.   Installation of the Tri-Sensor Adapter on 

an AKC13 Front Board

4. 

For PureLink systems only:

 

 

For all PureLink systems with AKC13 front 

board, an additional cable assembly part number 

R0538600 is required due to the limited space 

between the AKC13 front board and the power 

center.

      

CAUTION   

 

       

Do not attempt to force the installation of the tri-sensor 

adapter directly into the AKC13 front board. The cable 

assembly P/N R0538600 must be used for proper operation 

and to avoid damaged to the tri-sensor board.

a.  Connect the cable assembly P/N R0538600 

to the tri-sensor adapter and the tri-sensor 

connector of the AKC13 front board.  

See Figure 4.

b.  Connect the tri-sensor cable 8-pin connector 

into the 8-pin male connector on the tri-sensor 

adapter.

5. 

For other systems:

 

a.  Connect the tri-sensor cable 8-pin connector 

into the 8-pin male connector on the tri-sensor 

adapter.

b.  Connect the 8-pin female connector of sensor 

adapter into the tri-sensor connector on the 

AKC13 front board.

7.  Turn ON power to the AquaPure/PureLink systems 

and circulation pump.

D.  Calibrate the Tri-Sensor Adapter

When installing a tri-sensor adapter to an existing 

AquaPure/PureLink systems or when replacing an 

existing tri-sensor adapter, the tri-sensor adapter must 

be calibrated as follows:

1.  Install the tri-sensor adapter as explained in 

Sections A and B of this document.

2.  Make sure to turn ON power to AquaPure/PureLink 

systems and circulation pump.

3.  Wait a minimum of four (4) minutes to stabilize the 

temperature readings of the tri-sensor.

4.  On the tri-sensor adapter, press and hold the 

calibration button for five seconds until the "Flow" 

indicator is illuminated. See Figure 5.

5.  The sensor is now properly installed.

Calibration 

Button

Flow Indicator Light

Jumper

Tri-Sensor Adapter

Figure 5.   Components of the Tri-Sensor Adapter