8
9. ELECTRIC DIAGRAM RED LINE+
IMPORTANT!
ELIMINATION OR SHUNTING OF ONE OF THE SAFETY OR REMOTE CONTROL ORGANS LEADS
AUTOMATICALLY TO THE CANCELLATION OF THE GUARANTEE
With an aim to improving its products, ZPCE reserves the right to modify the characteristics
without prior notice
- Edition 01/2009
black or
grey sheath
LEGEND:
CD:
flow switch
F1:
protection fuse 3.15 A-T
L1:
“on/off” led
L2:
led “reg” blinking when temporisation in process, steady
while operating
S1:
“on/off” switch
So:
pool water regulation probe
TH:
control thermostat with digital display
KM1:
power contactor
R:
heating element titanium
TS: safety thermostat positive (triggering at 63°C, manual
reset)
Electronic connections :
N-R-S-T: connection 230V-1N-50Hz
(terminals R-S-T and C-N shunted)
or 400V-3N-50Hz
: grounding
Regulator with digital display
Black cable with clips of colors*
Case: Red Line in 12 Kw 400 V / 50 Hz
three-phase box
CAUTION !
12 Kw model shall be
connected only to
400V/3N/50Hz mains
supply
*
power engraved on the metal resistor cup
V-j:
green-yellow
Bl:
blue
M:
brown
B:
white
N:
black
R:
red
Vi:
violet