2.1 Recommendations

WARNING: THE PH PERFECT MUST BE INSTALLED BY AN EXPERIENCED POOL 
PROFESSIONAL.
> SHOULD PH PERFECT REQUIRE ANY ELECTRICAL MAINTENANCE ALWAYS DISCONNECT 
THE APPLIANCE FROM THE POWER SUPPLY.
>  

Before installing the pH Perfect controller, make sure that you have all the components required and 
that you have read the instruction manual carefully.

>  

Failure to comply with the instructions contained in this manual can be dangerous, cause damage to 
the appliance and may void the warranty.

>  

While installing the pH Perfect controller, make sure of the following:

 

•  The supply voltage is as indicated on the label attached to the side of the appliance

 

•  The electric installation is compliant with NF C15-100 standards (or equivalent for other European 

countries). 

 

•  The pressure at the injection point is less than 1.5 bar

 

•  The protective housing on the pump is properly clipped into position

 

•  The suction tube is immersed with the intake pipe in the container of corrective solution to be 

injected and is connected to the pump (on the left). Then retighten the nut on the connector

 

•  The inlet tube will then be connected to both the pump (on the right), and the inlet pipe to the 

pool through the injection fl ap valve.

>  

Do not use hydrochloric acid, use pH corrective products as recommended by your pool specialist. 
Zodiac Pool Care Europe cannot be held liable if unsuitable products are used.

2.2 Technical details

Dimension (L - W - H) 

240 x 200 x 90 mm

Weight (appliance, sensor, tube and pipes)  1.7 kg
Power feed 50Hz 

220-240 V AC/50 Hz 

Consumption 

12W

Pump fl ow rate 

1.5 l/hr

Maximum backpressure 

1.5 bar

pH control range 

0.0 pH-14.0 pH

Appliance accuracy 

+/- 0.1 pH

Calibration of the sensor 

Semi-automatic in 2 points (1 point possible)

2.3 Installation diagram

Installation of the pH Perfect on the fi ltration system:

THE DISTANCE BETWEEN THE 
SENSOR AND THE INJECTION POINT 
MUST NOT BE LESS THAN 60 CM.

The injection point must be the last 
element on the return line before the 
pool.
Keep the sensor cable away from other 
power cables and large pump supply 
cables in order to prevent electrical 
interference. 
The maximum pressure in the pipes must 
not exceed 1.5 bar.
To increase the life span of the peristaltic 
pipe, the pressure should not exceed 
1 bar. 
If the pool has a heating system or any 
other equipment, they must be situated 
after the pH sensor but before the liquid 
chlorine injection point.

2

60 cm mini

4

OPTION: NOT INCLUDED I N THE PACKAGING: POD KIT

The “POD Kit” is an accessory used to group together the measurement 
sensors when jointly using a pH Perfect and a Zodiac Chlor Perfect (or 
other regulation with a 12 mm diameter sensor).

The “POD Kit” includes a multi-diameter fi xing collar (DN 50 mm or DN 
63 mm) and a measurement chamber in order to obtain more reliable 
results (+ assembly accessories).

The “POD Kit” is available from your reseller.

2.4 Installing the control unit and electrical connections

Install the pH Perfect controller on a rigid support (vertical wall) in an easily accessible place.

The electrical connections for the pH Perfect must be done by an experienced pool professional.

“Standard” pH Perfect electric connection:

2.5  Installing the sensor and the injection point

The sensor must be vertical or up to 45° maximum, and always above the rigid pipe. It must NEVER be 
located horizontally or below the rigid pipe.

Correct positions 

Incorrect positions  

Drill a hole between 16 and 22 mm on the pipe at the location selected for the pH sensor and for the 
injection point (see diagram in paragraph 2.3). Next fi t the fi xing collars by aligning them opposite the 
drilled holes.

Use the Tefl on

®

 tape to make sure that the threads of the sensor holder, injection valve and adapter 

are watertight.

CT 

220-240 V AC 

50 Hz

L

30 mA 

N

220-240 V AC 

50 Hz 

220-240 V AC    

50 Hz 

5

22

23

EN

Summary of Contents for pH Perfect

Page 1: ...osage 10 4 5 Alkalinity level 10 4 6 OFA over feed protection 10 4 7 Type of calibration 11 4 8 Detection that ltration is in progress 11 4 9 Resetting the appliance 11 Care and maintenance of your pH...

Page 2: ...Blue Backlighted LCD 1 line 16 white character screen Left side warning zone alarms Right side pH display 2 Peristaltic pump 3 Connection for linking polyethylene inlet tube 4 Connection for linking...

Page 3: ...n the ltration system THE DISTANCE BETWEEN THE SENSOR AND THE INJECTION POINT MUST NOT BE LESS THAN 60 CM The injection point must be the last element on the return line before the pool Keep the senso...

Page 4: ...appliance indicates the measurement reliability of the sensor expressed as a percentage 7 After 30 seconds the appliance indicates the measurement reliability of the sensor expressed as a percentage...

Page 5: ...age displayed on the pH Perfect is French A You can choose between 6 languages for the LCD display French English German Spanish Italian and Dutch To change language when in the Settings menu enable t...

Page 6: ...Accept the choice by pressing the CAL Enter button E F Special functions of the OFA To prevent false alarms just after installing a pH Perfect if the pH is poorly balanced and the chlorine needed ther...

Page 7: ...larly during the bathing season Zodiac Pool Care Europe cannot be held liable if these rules are not followed To fit your pool with a global automated water treatment system we recommend that you use...

Page 8: ...arranty on spare parts shall only be effective after an analysis and expertise by our company of the returned parts followed by the decision to replace them In all cases the legal vendor warranty cont...

Reviews: