Page 46/68
INSTALLATION AND CIRCUIT – Connection of options
IV-2-8-CONNECTION OF OPTIONS
IV-2-8-1-Precautions
The boat is fitted as standard or version with 2 bilge pumps, navigation lights, a shower kit,
lighting for the deck and cabin and drain facilities for the toilet. However, 2 locations remain
available on the fuse box (under the console) for the connecting of additional accessories
under certain conditions:
c
The accessories you want to add must be connected at the level of the console.
d
Accessories are divided into two categories:
A
Æ
accessories that are used or which may be used continuously during normal use of
the boat,
B
Æ
accessories that are used intermittently.
A
and
B
Bilge fan
Cigar lighter connector
Radio
Miscellaneous
lighting
Depth sounder
Audio warning
GPS
Miscellaneous
electronic
equipment
Searchlight
Shower
pump
Alarm system
Max power
60W max
Refrigerator
VHF
Σ
180W max
WARNING
You must make sure that the total power of the accessories in
column A you add is 180W (15A) or less AND the max power of
an accessory in column B is 60W (5A) or less.
The sections of the cables in the harness were calculated using
these values; if this rule is not adhered to, electrical malfunctions
and short-circuits may result.
You may connect the options directly to the positive and negative console bus bars (within the
max. power limits), using an approved fuse-holder.
Summary of Contents for NZO 700
Page 1: ...Page 1 68 E N G L I S H Owner s Manual Volume 2...
Page 32: ...Page 32 68 INSTALLATION AND CIRCUIT Electricity IV 2 Electricity IV 2 1 Layout diagram...
Page 62: ...Page 62 68 LABELLING V 2 DESCRIPTION OF SAFETY LABELS AND REGISTRATION PLATES 1 4 3 2...
Page 66: ...Page 66 68 LOCATION OF OPTIONAL ACCESSORIES VI 3 PLOTTER VHF not supplied VHF Plotter...