Set Point Lockout
Make sure the control is in the ON mode (POOL or SPA), press
and hold the Up and Down buttons for 7 - 10 seconds. The set
point will be locked and the control will operate in the mode it was
in when the Set Point Lockout occurred. If an attempt to change
the set point is made while the control is in Set Point Lockout, the
control will display SET POINT LOCKED. To unlock the Set Point
Lockout, press and hold the UP and DOWN buttons for 7 - 10
seconds. The unit will display SET POINT UNLOCKED.
Example of Set-Up for RS Controls
STEP 1
With the Control set to OFF, switch to the Service Setup
menu by pressing MENU, then POOL button and SPA
button, holding all three buttons simultaneously for 7 to 10
seconds.
STEP 2
Press the DOWN button until the screen reads REMOTE.
To return to a previous screen any time, press MENU.
STEP 3
When REMOTE is displayed, press the MENU button.
STEP 4
Press either the UP or DOWN button to change the display
to HI-LO-COM (3 wire) or T-STAT (2 wire connection).
STEP 5
Press MENU to select.
STEP 6
Press POOL or SPA to exit Service Setup and return to the
heater control screen.