Zodiac Jandy LXi Pro Series Quick Manual Download Page 2

H0295900 REV B

Set Point Lockout

Make sure the control is in the ON mode (POOL or SPA), press 
and hold the Up and Down buttons  for 7 - 10 seconds. The set 
point will be locked and the control will operate in the mode it was 
in when the Set Point Lockout occurred. If an attempt to change 
the set point is made while the control is in Set Point Lockout, the 
control will display SET POINT LOCKED. To unlock the Set Point 
Lockout, press and hold the UP and DOWN buttons for 7 - 10 
seconds. The unit will display SET POINT UNLOCKED.

Example of Set-Up for RS Controls

STEP 1

 

With the Control set to OFF, switch to the Service Setup 

menu by pressing MENU, then POOL button and SPA 

button, holding all three buttons simultaneously for 7 to 10 

seconds.

STEP 2

 

Press the DOWN button until the screen reads REMOTE. 

To return to a previous screen any time, press MENU.

STEP 3

 

When REMOTE is displayed, press the MENU button.

STEP 4

 

Press either the UP or DOWN button to change the display 

to HI-LO-COM (3 wire) or T-STAT (2 wire connection).

STEP 5

 

Press MENU to select.

STEP 6

 

Press POOL or SPA to exit Service Setup and return to the 

heater control screen.

1

2

3

ZODIAC®

  is a registered trademark of Zodiac International, S.A.S.U, used under license. 

 

All other trademarks referenced herein are the property of their respective owners. 

 

©2014 Zodiac Pool Systems, Inc.