Optional Remote Set-up
Heater Controls Quick Guide
Operating Modes
• Pool or spa will heat only when the filtration system is
running and the control has been turned ON for either
POOL or SPA as indicated by a green LED above
either POOL or SPA button.
• Maintain Temperature (Auto-Heat) will allow the
heater to check the pool temperature periodically and
override time clock settings, heating the pool or spa
whenever the temperature falls below the set point.
This feature on the heater requires additional field
wiring and optional relay.
Normal Operation
• When Zodiac (Z) icon is lit, the unit has power.
• Choose Pool or Spa. Each has its own set
temperature.
• Temperature may be raised or lowered using UP or
DOWN arrow buttons.
• Red LED above POOL or SPA button indicates the
unit is heating.
• Green LED above POOL or SPA button indicates
the unit is ON in pool or spa mode and heater has
reached desired set temperature.
User Set-up Mode
With the unit OFF, press and hold MENU for 7-10
seconds. Use UP / DOWN arrow keys to toggle between
the functions. The MENU key toggles various options
within the functions. Press POOL or SPA button to end
Setup Mode and return to OFF.
User Set-up Functions
1) Language Selection .
Select English, Spanish or French.
2) Temperature Scale.
Select Fahrenheit or Celcius scale.
3) Spa Timer .
Provides automatic shut down of spa operation.
4) Display Lighting.
Controller lights can be set ON, OFF or to SHUT OFF
after a two minute delay.
Refer to the heater installation and operation manual
for complete descriptions of each function.
Service Set-up Mode
With the unit OFF, press MENU, and POOL button and
SPA button simultaneously. Hold all three buttons for
7 - 10 seconds.
The UP / DOWN arrow keys toggle between the
different functions. The MENU key toggles various
options within the functions. The POOL & SPA keys end
the Setup Mode and return to ‘OFF’.
Service Set-up Functions
1) Maintain Temperature
2) Maintain Temperature Delay
3) Remote Thermostat
4) Freeze Protect
5) Louver (LXi models only)
6) Load Defaults - Resets factory settings
7) Air Temperature Calibration
8) Water Temperature Calibration
9) Water Temperature Differential
10) Statistics
11) Last Fault
Refer to the heater installation and operation manual
for complete descriptions of each function.
Maintain Temp Set-up
This feature requires additional field wiring and an
optional relay. Follow directions from Service Set-up
Mode (see above), Maintain Temperature (Service
Set-Up Function 1). To operate in pool mode with the
Maintain Heat feature, press POOL, then press MENU,
press the Down button until MAINTAIN POOL HEAT is
displayed, then press the MENU button.
The green LED indicator lights and the unit will display
SET: XXº. Change the temperature set point by
pressing the UP or DOWN button until the desired set
point is displayed. After 5 seconds of inactivity, the new
set point is stored in memory.
An optional control can be installed remotely with 22AWG
4 conductor wire up to 300’. The additional control can be
wired in a pool house or in the home. All wiring must be done
in accordance with applicable local and National codes and
requirements.
AquaLink
®
RS/Remote
• Wire as shown in Figure 2.
• Enter Service Set-Up mode (see right). Choose Remote
Thermostat (Service Setup Functions #3, see right).
Display will show REMOTE on the second line.
• Use UP/DOWN arrows to toggle: ‘OFF’, ‘HI-LO-COM’, or
‘REMOTE T-STAT’. For Aqualink RS connection choose
’REMOTE T-STAT’.
• Press MENU to save selection. Press either POOL or SPA
to exit Service Set-Up mode.
• Press POOL or SPA button, then UP arrow key to
raise spa temperature set point to maximum (104°F).
Control will indicate either Pool or Spa enabled and flash
REMOTE T-STAT ENABLED.
Figure 3.
AquaLink RS 485
Communication
(4-Wire
Connection)
Figure 1.
Remote Pool-Off-
Spa Connection
(3-Wire
Connection)
Figure 2.
AquaLink RS or
Remote TSTAT
Connection
(2-Wire
Connection)
AquaLink RS 485
• Wire as shown in Figure 3.
• Display shows JANDY REMOTE ONLINE PUSH MENU
TO DISABLE. The heater control panel is now disabled.
• To temporarily use the heater controls, press MENU and
all functionality will return to the heater control.
• To return functionality to the RS remote, press MENU for
5 seconds to enter the User Set-up mode and then enable
the remote.
WARNING
TO AVOID PROPERTY DAMAGE, INJURY
OR DEATH, BE SURE TO READ THE
“CONSUMER INFORMATION AND SAFETY”
SECTION IN THE HEATER INSTALLATION
AND OPERATION MANUAL.
LXi
™
Heaters
JXi
™