Zodiac Jandy LXi Pro Series Quick Manual Download Page 1

Optional Remote Set-up

Heater Controls Quick Guide

Operating Modes

•  Pool or spa will heat only when the filtration system is 

running and the control has been turned ON for either 

POOL or SPA as indicated by a green LED above 

either POOL or SPA button.

•  Maintain Temperature (Auto-Heat) will allow the 

heater to check the pool temperature periodically and 

override time clock settings, heating the pool or spa 

whenever the temperature falls below the set point. 

This feature on the heater requires additional field 

wiring and optional relay.

Normal Operation

•   When Zodiac (Z) icon is lit, the unit has power. 

•   Choose Pool or Spa. Each has its own set 

temperature. 

•   Temperature may be raised or lowered using UP or 

DOWN arrow buttons. 

•   Red LED above POOL or SPA button indicates the 

unit is heating.

•   Green LED above POOL or SPA button indicates 

the unit is ON in pool or spa mode and heater has 

reached desired set temperature. 

User Set-up Mode

With the unit OFF, press and hold MENU for 7-10 

seconds. Use UP / DOWN arrow keys to toggle between 

the functions. The MENU key toggles various options 

within the functions. Press POOL or SPA button to end 

Setup Mode and return to OFF.

User Set-up Functions

1)   Language Selection . 

 

Select English, Spanish or French. 

2)   Temperature Scale.

 

Select Fahrenheit or Celcius scale.

3)   Spa Timer .

 

Provides automatic shut down of spa operation.

4)   Display Lighting.

 

Controller lights can be set ON, OFF or to SHUT OFF 

after a two minute delay.

  

Refer to the heater installation and operation manual 

for complete descriptions of each function.

Service Set-up Mode

With the unit OFF, press MENU, and POOL button and  

SPA button simultaneously. Hold all three buttons for 

 

7 - 10 seconds.

The UP / DOWN arrow keys toggle between the 

different functions. The MENU key toggles various 

options within the functions. The POOL & SPA keys end 

the Setup Mode and return to ‘OFF’.

Service Set-up Functions

1)  Maintain Temperature

2)  Maintain Temperature Delay 

3)  Remote Thermostat 

4)  Freeze Protect

5)  Louver (LXi models only)

6)  Load Defaults - Resets factory settings

7)  Air Temperature Calibration

8)  Water Temperature Calibration

9)  Water Temperature Differential

10)  Statistics

11)  Last Fault 

Refer to the heater installation and operation manual 

for complete descriptions of each function.

Maintain Temp Set-up

This feature requires additional field wiring and an 

optional relay. Follow directions from Service Set-up 

Mode (see above), Maintain Temperature (Service 

Set-Up Function 1). To operate in pool mode with the 

Maintain Heat feature, press POOL, then press MENU, 

press the Down button until MAINTAIN POOL HEAT is 

displayed, then press the MENU button.

The green LED indicator lights and the unit will display 

SET:  XXº. Change the temperature set point by 

pressing the UP or DOWN button until the desired set 

point is displayed. After 5 seconds of inactivity, the new 

set point is stored in memory.

An optional control can be installed remotely with 22AWG 

4 conductor wire up to 300’. The additional control can be 

wired in a pool house or in the home. All wiring must be done 

in accordance with applicable local and National codes and 

requirements.

AquaLink

®

 RS/Remote

•   Wire as shown in Figure 2. 

•   Enter Service Set-Up mode (see right). Choose Remote 

Thermostat (Service Setup Functions #3, see right). 

Display will show REMOTE on the second line.

•   Use UP/DOWN arrows to toggle: ‘OFF’, ‘HI-LO-COM’, or 

‘REMOTE T-STAT’. For Aqualink RS connection choose 

’REMOTE T-STAT’.

•  Press MENU to save selection. Press either POOL or SPA 

to exit Service Set-Up mode.

•  Press POOL or SPA button, then UP arrow key to 

raise spa temperature set point to maximum (104°F). 

Control will indicate either Pool or Spa enabled and flash 

REMOTE  T-STAT ENABLED.

Figure 3.

 

AquaLink RS 485 

Communication 

(4-Wire 

Connection)

Figure 1.

  

Remote Pool-Off-

Spa Connection  

(3-Wire 

Connection)

Figure 2.

 

AquaLink RS or 

Remote TSTAT 

Connection  

(2-Wire 

Connection)

AquaLink RS 485

•  Wire as shown in Figure 3.

•   Display shows JANDY REMOTE ONLINE PUSH MENU 

TO DISABLE. The heater control panel is now disabled.  

•   To temporarily use the heater controls, press MENU and 

all functionality will return to the heater control.

•   To return functionality to the RS remote, press MENU for 

5 seconds to enter the User Set-up mode and then enable 

the remote.

WARNING

TO AVOID PROPERTY DAMAGE, INJURY 

OR DEATH, BE SURE TO READ THE 

“CONSUMER INFORMATION AND SAFETY” 

SECTION IN THE HEATER INSTALLATION 

AND OPERATION MANUAL.

LXi

 Heaters

JXi

 Heaters

Reviews: