5
EN
Switchover from automa� c mode to "Quick Clean" mode (default: maximum speed
3450 RPM for 30 minutes)
Ac� vates "Wi-Fi to phone" mode for advanced confi gura� on during installa� on (direct
Wi-Fi between the smartphone and the pump = light on).
Selects Service mode:
-
"OFF": pump stopped manually
-
"Timed Stop": delayed pump start (default: a� er 3 hours)
-
"Timed Run": � med pump opera� on (default: for 3 hours at 2750 RPM)
To return to automa� c mode, press
Se� ngs and remote access via the iAquaLink™ app
•
Download and install the iAquaLink™ app on your smartphone and/or tablet (Apple® or Android™).
•
Open the app and create a user account where necessary.
•
Follow the steps shown in the app to:
Can be performed by
the fi � er
the user
Add the iQPUMP to your user
account
Save the pump’s default
se� ngs
Confi gure the connec� on to
the home Wi-Fi network
•
The device must be installed by a qualifi ed technician.
•
Disconnect the power supply to the fi ltra� on pump and the device before you do anything.
•
iQPUMP device must ONLY be powered by the fi lter pump.
•
To avoid damage to the equipment, wait 1 minute before opening its electrical compartment.
Electrical connec� on
•
Disconnect the power supply to the pump and wait 1 minute before opening its electrical
compartment located at the rear (secured using a screw).
•
Run the device’s RS485 cable into the pump’s second grommet.
•
Connect the cable to the connector provided as indicated in the diagram
(1 = red, 2 = black, 3 = yellow, 4 = green).
•
Connect the connector to the terminal provided for this purpose in the electrical compartment of
the pump.
If the pump has a user interface, disconnect its RS485 connector fi rst (the interface then becomes
inacti ve)
.
•
Check that the switches are correctly posi� oned (1-2-5 = ON, 3-4 = OFF)
.
•
Reconnect the pump to the power supply, the
indicator lights up on the iQPUMP.