2
1. GENERAL
1.1 General terms of delivery
Any equipment, even CARRIAGE and PACKING FREE, travels at the consignee's risk. The consignee
shall make reserves in writing on the carrier's delivery bill if he notes damage caused during the
transport (confirmation to be sent to the carrier within 48 hours by registered mail and Acknowledgement
of Receipt).
1.2 Voltage
Prior to any operation, check that the voltage on the identification plate of the appliance corresponds to
the mains voltage provided on site.
1.3 Water treatment
In order to use our appliances in the best conditions, swimming pool water shall comply with the
following values: free chlorine: max. 2.5 mg/L, total bromine: max. 5.5 mg/L, pH between 6.9 and 8.0.
For any other treatment, the fitter and the user shall apply to the supplier of the planned disinfection’s
process (chemical, electrochemical or electro-physical) for the compatibility with the materials of our
appliances. In any case, treatment shall be installed downstream the heating equipment.
2. DESCRIPTION
2.1 Presentation
Note
: drain plug is in Ø15/21.
2.2 Dimensions
Dimensions in mm
A
B
Heatline in case 20
535
198
Heatline in case 40
535
198
Heatline in case 70
665
328
Digital regulation ther “on/off”
button and heating indicator
Cover fixing
screw
fittings ½ union PVC Ø63 + reduction Ø50
Screw permitting
access to the
electrical box
Flow rate
controller
Check valve
Ø26/34
¼ turn
valve
Ø26/34
drain plug for primary
circuit
multitubular titanium
heat exchanger
orifice blocked (with threading Ø
26/34 female) on exchanger body 70
kW:
never use a primary circuit
connection
!
Circulator
¼ turn valve
Ø26/34
thermostat
Stuffing box
Only on
Heatline in
case 70
*dimension with ±1mm
Power supply cable 2P-T 10/16A 3G1
Male heating fitting Ø26/34 +
solder fitting Ø20/22