EVAC 90, SQUATTING TOILET

Trouble

Squatting toilet is discharging
contineously (discharge valve
open).

Bowl is not emptying, but water
comes (high water in bowl).

No water, but otherwise flushing
or too little rinsing water

Toilet is overflowing.

Toilet does not flush.

Cause

• Foreign object in the bowl or in the

discharge valve

• Blocked bowl
• Blocked discharge valve
• Loose / clogged hoses
• Water shut-off valve closed
• No water pressure
• Filter in water valve full of dirt
• Flush ring loose
• Flush ring clogged
• Strainer blocked up
• Water valve jammed in open

position

• Bowl clogged or discharge valve not

operating

• Misuse (buckets of water thrown in

the bowl)

• Too low vacuum (less than 30%) to

flush

• No vacuum or low vacuum (less

than 30kPa)

• Clogged mini check valve
• No impulse from flush knob
• Jammed control mechanism

Remedy

• Shut off the problematic branch line

valve.

• Remove foreign object.
• Change discharge valve.
• Check and if necessary change the

control mechanism.

• Clean bowl / clean valve / connect

vacuum hoses.

• Connect hoses
• Open valve
• Provide water pressure
• Clean filter
• Connect flushing ring
• Clean flushing ring
• Clean strainer
• Close water shut-off valve
• Clean / change water valve nozzles,

springs, rubbers

• Discharge bowl, valve, piping

with by-pass or / hose connections

• Check vacuum level, remove

blockage in piping

• Clean / change mini check valve
• Check hoses and push button. The

triangle must face upwards and the
tip of the triangle must point towards
the sewage piping.

Shut-off valve

Strainer

Vacuum breaker

Pneumatic push button

Water valve

Discharge valve

Vacuum hoses

Control mechanism

Water supply hose

Summary of Contents for EVAC 90

Page 1: ...ng data Water pressure 200 600kPa Recomended water pressure 250 350kPa Operating vacuum 30 50kPa Water consumption 1 5 2 5 litres flush adjustable Air consumption 60 10 litres flush normal atmospheric...

Page 2: ...rcial Marine Equipment V V V V VA A A A ACUUM CUUM CUUM CUUM CUUM T T T T TOILET OILET OILET OILET OILET TECHNICALDATA Date Doc 28 Jan 2005 1 01199A 5900200 PNEUMATIC PUSH BUTTON EVAC 90 SQUATTING TOI...

Page 3: ...360 Different positions can be used Straight connection tube can be used instead of elbow Connection upwards shown only as an example 700 Tiling Floor Water connection Flushingwaterconnection R 1 2 BS...

Page 4: ...ET INSTALLATION Date Doc 25 Jan 2005 2 01016B 5900200 PNEUMATIC PUSH BUTTON EVAC 90 SQUATTING TOILET Put the slide guide tap to the groove on a cover Snap on the cover and the push button Slide guide...

Page 5: ...water valve opens and lets rinsing water into the squatting bowl through a hose nipple After a short delay the vacuum acts in discharge valve housing and forces the rubber diaphragm in discharge valv...

Page 6: ...check valve 13 to discharge valve 18 and water valve 19 which will both open Chamber 14 is also subjected to vacuum through check valve 21 This vacuum will pull lever 8 and close valve 1 and the time...

Page 7: ...1025C pos 4 counters the effect of quick changes in the vacuum supply Jet 3 doc 3 01025C pos 15 delays the vacuum changes in chamber 14 see doc 3 01025C This prevents a new flushing procedure to start...

Page 8: ...Vacuum hose Controlmechanism Operation Closed condition In the closed position the control valve shuts off the connection between the vacuum piping and the discharge valve housing As the valve housin...

Page 9: ...Water valve filter 5774150 Clean Control mechanism air filter 5778600 Check operation push button seat and cover rinse pattern discharge pattern Check possible water and vacuum leakage Every 10 years...

Page 10: ...tion Bowl clogged or discharge valve not operating Misuse buckets of water thrown in the bowl Too low vacuum less than 30 to flush No vacuum or low vacuum less than 30kPa Clogged mini check valve No i...

Page 11: ...tedasshown Alsocheckthatrubberdiaphragmisinrightposition see pictureabove Fig 2 Fig 1 Fig 4 Fig 3 Rubbersleeve Rubbersleeve Rubberdiaphragm Lightly spread Dismantling of the discharge valve 1 Compress...

Page 12: ...ingpan 6542811 DISCHARGEVALVE ASSEMBLY 6543029 Recommended spare part kit 1 x 5435169 Rubberdiaphragm 2 x 5435181 Rubbersleeve 5990210 Hose clamp 5935503 Hose 5990210 Hose clamp 5778992 Water hose 543...

Page 13: ...for this jet available 5778000Jetcarriercomplete 5778002Jetcarriercomplete 5778004Jetcarriercomplete 5778600 Air filter Jet Carrier identification P N Colour Size Effect 5778004 Yellow 0 20 Extra lon...

Page 14: ...notice CopyrightEvacOy Allrightsreserved 1 EVAC Commercial Marine Equipment V V V V VA A A A ACUUM CUUM CUUM CUUM CUUM T T T T TOILET OILET OILET OILET OILET SPARE PARTS Date Doc 25 Jan 2005 6 01030C...

Reviews: