INST 473 ZODIAC EL24 Salt Chlorinator V10.18
8
CELL CLEANING INSTRUCTIONS:
-
Close applicable valves
-
Disconnect the chlorinator from the mains by removing the 3 pin plug
-
Disconnect the cell wires
-
Undo the barrel nuts connecting the cell to your filtration system
-
Turn the cell upside down (inlet and outlet on top) and fill the cell with a mix of 1 part
Hydrochloric acid to 10 parts water and leave standing for a few minutes. As an
alternative, you may use an approved commercial Cell cleaning solution
-
Repeat if necessary and then rinse well in clean water
-
Re-install the cell ensuring o-rings are correctly located and barrel nuts are tightened to
prevent leaks
-
Re-connect cell wires ensuring all connections are in the proper colour coded connecter
-
Return all valves to their normal positions, re connect power to the chlorinator and turn
on at power point.
WARNING: Follow safety instructions provided with the Hydrochloric acid or cleaning
solution. When handling Hydrochloric Acid, the use of eye protection, mask and gloves are
highly recommended. Extreme caution should be taken whenever handling Hydrochloric
Acid or Cell Cleaning Solution.